1. Unscrew the ring.
2. Separate the two parts of the housing.
3. Disconnect the battery connector.
4. Check that the new battery is marked with date of expiration.
5. Place the new gasket on the battery housing.
6. Connect the battery connector.
7. Replace the upper part, taking care that the gasket is correctly fitted.
8. Replace the screw ring.
9. Perform a Self-test.
6.1.3
BATTERY DISPOSAL
Dispose in accordance with applicable regulations, which vary from country to country.(In most countries, the thrashing
of used batteries is forbidden and the end-users are invited to dispose of them properly, eventually through non-profit
organizations, mandated by local governments or organized on a voluntary basis by professionals).Lithium batteries
should have their terminals insulated prior to disposal.
6.1.4
INCINERATION
Incineration should never be performed by battery users but eventually by trained professionals in authorized facilities
with proper gas and fumes treatment.
6.1.5
LAND FILLING
Leachability regulations (mg/l)
Component Leachability EC
limit
EPA Other*
Iron
Nickel
100
100
500
2
5
0,5
* Applicable to France
6.1.6
RECYCLING
Send to authorized recycling facilities, eventually through a licensed waste carrier.
6.2
TRON 45S/SX SELF TEST
1.
Remove the EPIRB from the bracket.
2.
Press the spring-loaded switch on top of the EPIRB to “TEST” position.
Keep hands and objects away from the antenna.
Summary of Contents for Tron 45S
Page 1: ...98955_UM_ 45S SX_E 1...
Page 27: ...98955_UM_ 45S SX_E 27 7 2 Bracket drawings 7 2 1 Bracket aluminium...
Page 28: ...28 98955_UM_ 45S SX_E 7 2 2 Bulkhead bracket 1 3 2...
Page 29: ...98955_UM_ 45S SX_E 29 7 2 3 MB45 bracket...
Page 30: ...30 98955_UM_ 45S SX_E Manual operation of the Tron 45SX See chapter 5 2 11...
Page 31: ...98955_UM_ 45S SX_E 31...
Page 32: ...32 98955_UM_ 45S SX_E 7 3 REPLACING BATTERY MODULE See chapter 6 1 2...
Page 33: ...98955_UM_ 45S SX_E 33 8 NOTES...
Page 34: ...34 98955_UM_ 45S SX_E...
Page 36: ...36 98955_UM_ 45S SX_E...