Safety Instructions

For Use By Qualified Personnel Only

When using your Mug Press,

basic precautions should always be followed,

including the following:

Read all instructions.

Use mug press only for its intended use.

Always keep the mug press dry.  Do not get the mug press wet to reduce the risk of electric shock.  

Avoid storing mug press in a wet/ damp area.  

Never pull the cord to disconnect the power. Instead, grasp plug and pull to disconnect from power 

outlet.

Make sure you protect the power cord by keeping it away from hot surfaces. Avoid placing objects 

on top of the cord.  This could cause damage to the cord and could be a fire hazard risk. 

Do not operate mug press with a damaged cord or if the equipment has been damaged.  To prevent 

risks of injury, please do not disassemble or attempt to repair the mug press by yourself if you are 

not qualify to do so. Instead, call or take it to a qualified service person for examination and repair. 

Incorrect assembly or repair could increase the risk of fire, electric shock, or injury to persons when 

the equipment is used.

If mug press being used by or near children, please make sure that it is supervised. Do not leave 

equipment unattended while connected.

Metal parts on the press can become hot.  Avoid touching the hot metal parts to prevent burns.  

Proceed with caution when using the mug press.

To reduce the likelihood of circuit overload, Joto recommends to use a dedicated circuit if possible.

Make sure that the cord is safely secured so it cannot be pulled or tripped over. 

If you need to use an extension cord, make sure you use a 20 amperage rated cord. Cords rated 

below 20 amperage can overheat. Make sure that the extension cord  is safely secured so it cannot 

be pulled or tripped over. 

Note:  Temperature is in Fahrenheit or Celsius.  This mug press should not be set to exceed 

400

˚

F (200

˚

C).  Setting the press temperature to above 400

˚

F(200

˚

C) will burn out your mug 

element and may cause a fire hazard.
Do not use any other power cords other than the one provided with this machine.  

 

Doing so may result in a fire hazard.  If you need a replacement cord, please call Joto at 

 

1800-565-5686 to request one.

 

PLEASE KEEP THE BOX THAT YOUR MUG PRESS ARRIVED IN, 

 

ALONG WITH ALL ORIGINAL PACKAGING.

Summary of Contents for E-HP-JMP-1S2E

Page 1: ...Joto Digital Mug Press Manual Single Station includes 2 Elements Model No E HP JMP 1S2E OPERATOR S MANUAL Bringing images to life TM TM Single Station Includes 2 elements ...

Page 2: ... repair could increase the risk of fire electric shock or injury to persons when the equipment is used If mug press being used by or near children please make sure that it is supervised Do not leave equipment unattended while connected Metal parts on the press can become hot Avoid touching the hot metal parts to prevent burns Proceed with caution when using the mug press To reduce the likelihood o...

Page 3: ...of this manual requires written consent from Joto Errors and amendments of technical details excepted all rights reserved Joto is not liable for any direct or indirect damages caused by the use of this product Table of Contents Safety 2 Introduction 3 Mug Press Overview 4 5 Machine Parts Diagram 6 Setting Up Your Mug Press 7 Elements Overview 8 Operating Instructions 9 Replacing The Mug Element 10...

Page 4: ...Mug Heater Size Dia 6 7 5cm for 6oz 9oz 10oz etc Mug Dia 7 5 9 0cm for 11oz 15oz etc Mug Voltage 220V 1Phase 110V 1Phase Power 10 3KW 1 36A Recommended Settings 30 280s 356 400 F or 180 200 C Time Range 0 999s Maximum Temp 400 F 200 C Packing Size 16 14 x 15 35 x 12 99 41 x 39 x 33cm Gross Weight 10 36lbs 4 75kg Note Temperature is in Fahrenheit or Celsius This mug press should not be set to excee...

Page 5: ...5 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Mug Press Overview TOP VIEW FRONT VIEW LEFT VIEW RIGHT VIEW ...

Page 6: ... com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Machine Parts Diagram Digital Controller Handle Bar Grip Mug Element Pressure Adjustment Knob Power ON OFF Switch Limit Switch ANGLED VIEW SIDE VIEW ...

Page 7: ...p and down arrows to choose to display in F or C F stands for Fahrenheit C stands for Celsius Once selection is made press OK to save Now use the arrow to change the value of the set temperature The left light in the middle is lit to indicate you are in the set temperature mode Setting Press Time Green Set Time Value will flash Use the up and down arrows to change the value Press OK to save the va...

Page 8: ...12oz Enamel Cup 14oz 17oz Travel Mug 16oz 20oz Beer Stein Water Bottle Element SKU X HP JMP 02 17oz Coke Shaped Bottle Water Bottle with Bamboo lid 650ml Aluminium Bottle with Straw Stainless Steel Water Bottle Aluminum Water Bottle Includes with mug press Available to purchase for additional cost 17oz Latte Element SKU X HP JMP 04 12oz Wine Cup with Lid 16 Stainless Steel Tumbler 17oz Latte 12oz ...

Page 9: ...he press Close the mug press Note Ensure the timer starts immediately after closing the press If it does not take the bottle out wait for the temperature to go up to the set temp 6 Timer will start counting down The press will beep when the set time has lapsed When mug press beeps open mug press and take out your drinkware 7a For sublimation peel immediately and dunk into warm cold water to stop t...

Page 10: ...r detailed instructions 4 With the Mug Press open unscrew the four screws that hold the mug element in place 5 Gently slide the mug element out of the mug press Please be careful not to damage the cord or the mug press 6 Gently slide the new mug element into the mug press 7 Re screw the four screws to keep the mug element in place 8 Connect the new mug element cord to the mug press Ensure that the...

Page 11: ...e rated life expectancy of an mug element is approximately 1000 2000 mugs Elements may wear out earlier due to other factors 1 No mug is in the press when on and the press is closed 2 Physical abuse 3 Environmental factors The mug element will start to cool down to room temperature if heat press stays unused for more than 30 minutes Note Temperature is in Fahrenheit or Celsius This mug press shoul...

Page 12: ...12 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Expanded Diagram ...

Page 13: ...5 15 Screw 2 3 Rubber Foot 5 16 Limit Switch 1 4 Female Socket 4 17 Nut 4 5 Power Cord 1 18 Connect Board 1 6 Fuse 1 19 Screw 12 7 Power Switch 1 20 Adapter Plate 1 8 Solid State Relay 1 21 Handle Bar Grip 1 9 Electrical Case Cover 1 22 Hex Head Screw 4 10 Screw 4 23 Heater Fixing Connector 1 11 Transformer 1 24 Small Mug Heater 1 12 GY 06 Digital Controller 1 25 Male Socket 1 13 Electrical Case 1...

Page 14: ...ww jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Circuit Diagram K0 Power Switch FU Fuse T Transformer EH1 EH2 Heating Pipe SJ Digital Controller R1 Relay ...

Page 15: ...nd JOTO will ship the replacement or repaired component freight prepaid by JOTO g This warranty is effective only if the product or component is installed in a location and manner prescribed by JOTO instructions and only if it is maintained in accordance therewith This warranty shall become ineffective if the product or component is altered by anyone other than JOTO employees JOTO neither assumes ...

Page 16: ...Bringing images to life TM TM www jotoimagingsupplies com Tel 1 800 565 5686 Fax 1 800 565 5622 Coquitlam BC Brampton ON Blaine WA Las Vegas NV Antioch TN ...

Reviews: