Jorvet J0558X User Manual Download Page 13

13

WARRANTY SERVICE

Limited Warranty

Jorgensen Laboratories warrants to the original purchaser that the products, not including 
accessories, shall be free from defects in materials and workmanship under normal use, if 
maintained in accordance with Jorgensen Laboratories’ guidelines and used according to its 
labeling, for the period specified in the manual.

Warranty Period – 5 Years from the Invoiced Date of Purchase

THIS  LIMITED  WARRANTY,  IS  IN  LIEU  OF  AND  EXCLUDES  ALL  OTHER  WARRANTIES 

WHETHER EXPRESSED OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, INCLUDING 

BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE.

This warranty is void if the product has been altered, misused, damaged by neglect or accident, 
tampered with, not properly maintained, not installed in strict compliance with applicable 
codes and ordinances, or repaired by persons not authorized by Jorgensen Laboratories. This 
warranty does not cover normal wear and tear and maintenance items and specifically excludes 
accessory items and any other equipment used with the product.

Limitation of Remedies

Jorgensen Laboratories’ only obligation under this limited warranty is the repair or replacement 
of the product. 

THIS IS THE EXCLUSIVE REMEDY.

 Jorgensen Laboratories shall not be liable 

for and hereby disclaims any direct, incidental, consequential or special damages or delays, 
including but not limited to loss of use, downtime, lost business, revenues and profits.

Warranty Procedure

To obtain warranty service, contact Jorgensen Laboratories:

800.525.5614  

|

  [email protected]

Jorgensen Laboratories Inc.  

|

  1450 N. Van Buren Ave.  

|

  Loveland, CO  80538

Summary of Contents for J0558X

Page 1: ...TOP LINE ANESTHESIA SYSTEM J0558X J0558Z USER MANUAL The JorVet Top Line Anesthesia System pictured above shows optional accessories J0558Y Bain Block and J0744SV Concentrator...

Page 2: ...e Maintenance Troubleshooting and Specifications Warranty and Service 03 04 05 06 07 08 09 10 11 12 13 Thank you for using our JorVet J0558X and J0558Z Anesthesia System We want you to get the most ou...

Page 3: ...3 TOP LINE ANESTHESIA SYSTEM MODELS J0558X J0558Z Shown with optional J0558Y Bain Block and J0744SV Concentrator IMPORTANT VAPORIZER NOT INCLUDED FOR BOTH MODELS...

Page 4: ...helf to provide more workspace and keep the patient s vitals and anesthesia controls in one area JorVet Top Line Anesthesia System Assembly u H Frame Stand Mounting Plate Assembly and Rebreathing Head...

Page 5: ...en flush will not work with a non rebreathing circuit The oxygen flush is only piped to the rebreathing absorber u Always operate inhalant anesthetic equipment with waste gas scavenging systems Failur...

Page 6: ...witch Rebreathing Non rebreathing 9 10 Pop off APL Valve 11 Rebreathing Bag Port Absorber Canister 12 13 Absorber Canister Knob 14 Manometer 15 16 Oxygen Flowmeter Flush Valve 1 2 Accessory Mounting A...

Page 7: ...r block positioned on the front face of the mounting plate and tighten Note Two people recommended for this step Mounting hardware supplied with vaporizer u Connect the inlet and outlet endcaps using...

Page 8: ...essure small green tubes from the anesthesia machine to the E tank regulator by pushing the tubing into the fittings Once resistance is felt continue to push the tubing slightly further to secure conn...

Page 9: ...g circuit NON REBREATHING CIRCUIT ATTACHMENT For use with animals that weigh approximately 15 lbs 7kg or less u Insert the adapter on the end of the long clear tubing into the Common Gas Outlet locate...

Page 10: ...N CARRIER GAS SUPPLY REGULATOR Compressed Tank in house or Concentrator Not needed for Concentrator Regulated Oxygen Carrier Gas Hose Anesthetic Agent and Oxygen Carrier Gas Mixture Flowmeter 0 4 LPM...

Page 11: ...tton or turn on oxygen flow meter until the bag is fully distended and or manometer reads 30 40 cm of H2O pressure Re open the pop off valve to your standard setting Squeeze the bag with your hand sti...

Page 12: ...gas system function attenuation 4 Confirm vaporizer has an adequate amount of agent 1 Tighten any loose connections vaporizer endcaps tubing connections 2 Replace breathing circuit or bag Fix loose co...

Page 13: ...maged by neglect or accident tampered with not properly maintained not installed in strict compliance with applicable codes and ordinances or repaired by persons not authorized by Jorgensen Laboratori...

Page 14: ...Jorgensen Laboratories Inc Loveland CO 80538 800 525 5614 fax 970 663 5042 www jorvet com info jorvet com Professional Veterinary Equipment Supplier...

Reviews: