5
TROUBLESHOOTING
MALFUNCTION
POSSIBLE CAUSE
SOLUTION
Machine does not turn ON
Power cord is not plug in into
wall receptacle.
Plug in the power cable.
Fuse broken.
Replace the broken fuse.
Main switch damage or broken. Replace Main power switch.
Control Panel is lit but nothing
happens when start button is
pressed
Broken Start button
Replace Start Button
Damage Sealing Head
Replace Sealing head
Work signal indicator is in order
but machine does not seal.
Input voltage out of range
Discontinue use until input
voltage is within operational
range
Insufficient sealing time.
Increase sealing time.
Materials of inductive liner and
sealing object are inconsistent.
Choose appropriate materials.
Damage Sealing Head
Replace Sealing Head.
Damage Main circuit board
Replace Main circuit board
Overheating light is ON (yellow
indicator)
High Temperature of main
components
Discontinue use until light turn
OFF.
Overcurrent light is ON (red
indicator)
Output current exceeds the
maximum value
Move induction head from jar
and cap surface until light
turns OFF