If the temperature of main components inside the machine is too high, the YELLOW light indicator,
on the front panel, will be ON and Overheating protection function activates, inductive output stops
automatically. Sealing shall not be done until temperature drops down and yellow indicators lights
off. Allow unit to cool for 5 minutes after 10 minutes of continuous use.
Control Panel
MAINTENANCE
IMPORTANT:
DO NOT Reach into the equipment, or any electrical enclosure, without first
removing the power. Always disconnect power before servicing, changing accessories or cleaning
the unit.
JORESTECH
®
Manual Induction Sealing Machines are designed to require minimal maintenance.
However, to ensure long-term reliability, it is a good practice to perform some preventive
maintenance actions.
Routine Inspection and Servicing
A weekly visual inspection is a good practice that will often identify issues before they affect the
equipment. You should check for dust and corrosive buildup on the system and hardware. Use low
pressure dry compressed air or a soft brush to remove dust for the machine components.
Inspect any cables or connectors for damage or deterioration. Cables must be free of kinks, cracks,
burns or discoloration along its entire length.
Inspect the sealing head. Make sure that sealing head housing is free of cracks or discolored from
overheating.
Inspect internal connections. Remove the top cover and front and back cover plate. Power and
control connections should remain tight. Loose connections may often be recognized by discoloration
of the wire or connector.