background image

 

USEFULL FEATURES 

 

You can manually open and close the valve by pushing the actuator towards the ballvalve and turning it left or right 90º  

(a visual check on the valves position can be done by checking the colour of the indicator: 
RED = OPEN 

NONE or BLUE = CLOSED 

(See figure 1) (ONLY ON THE 1” VERSION) 

You can change the position of the actuator on the valve by turning the actuator (see figure 1).  

Note. This will influence the OPEN and CLOSE setting (OPEN will become CLOSE and CLOSE will become OPEN). 

 

Air-Saver 1” housing 

 

Figure 1 

 

Air-Saver 2” housing 

 

Figure 2 

Note: On the 2” version (figure 2), you can manually open/close the valve by turning the knob on top of the actuator. 

 
 

TECHNICAL SPECIFICATIONS 

 
Power supply 

    

115VAC or 230VAC (see label) 

Power consumption 

7W during the opening and closing of valve 

Opening/closing time 

30 seconds / 90º for the 1” version 

 

 

 

105 seconds /90º for the 2” version  

Max. ambient temp. 

55ºC 

Max. medium temp. 

100ºC 

Max. pressure 

 

16 bar / 230 psi

 

IP rating  

 

IP 54 

Manual override   

Yes 

Max. switching points 

16 per day / 112 per week 

Min. switching point 

1 minute 

Timer display 

 

24 hrs 

Timer battery live 

1-2 years expected, not guaranteed  

 

Summary of Contents for Air-Saver 1"

Page 1: ...ith types of fluids or gasses as stated in its documentation Usage of this product in conditions not specified in the product documentation or contrary to the instructions hereby provided is considered IMPROPER The manufacturer will not be held liable for any damages resulting from improper use of the product ATTENTION Observe valid and generally accepted safety rules when planning installing and ...

Page 2: ...________________________________________________ Motorised Ballvalves usually operate in any mounting position We recommend however that the valve is mounted according to these drawings ______________________________________________________________________________________________________ Minimum space required around the unit is 100 mm ______________________________________________________________...

Page 3: ... the day 8 Mon 1 Tue 2 We 3 Form time blocks Mon Fri 1 2 3 4 5 Mon Sat 1 2 3 4 5 6 Mon Sun 1 2 3 4 5 6 7 The day must be set otherwise the switching point will not be activated 4th Step By pressing the 9 key you save the switching point data and go on to the next switching point CLOSE The display will show You can now set the time and day for closing the valve By pressing the 9 key you save the sw...

Page 4: ...nd CLOSE will become OPEN Air Saver 1 housing Figure 1 Air Saver 2 housing Figure 2 Note On the 2 version figure 2 you can manually open close the valve by turning the knob on top of the actuator TECHNICAL SPECIFICATIONS Power supply 115VAC or 230VAC see label Power consumption 7W during the opening and closing of valve Opening closing time 30 seconds 90º for the 1 version 105 seconds 90º for the ...

Page 5: ...n the top cover Identify the remote switching cable sides Slide the remote switching cable through the cable gland Connect the RED remote cable with the RED cable of point 3 Slide the RED cable back into its place marked with the number 3 Connect the BLUE remote cable with the BROWN cable of point 5 ...

Page 6: ...ct the BLACK remote cable with the GREY cable of point 4 Slide the BLACK GREY cables back into its place mark with the number 4 Slide the BROWN remote cable onto point 5 A complete look at the cable set up Tighten the 4 screws and the cable gland ...

Page 7: ...k displaying the correct time TROUBLESHOOTING Check whether the valve has been rotated manually This could interfere with the programmed OPEN and CLOSE times i e the OPEN times could become the CLOSE times and visa versa Check supply voltage Check pressure ...

Reviews: