3
CONTROL PANNEL
1 Mode
selector
switch 1
(operation mode)
2 Mode
selector
switch 2 (setting
time, program)
3 LCD
display
4 Override
button
5 Setting
the
minutes
6
Setting the hours
7 RESET
8 Setting
the
days
9 Programming
of
timer (saving
settings)
PROGRAMMING INSTRUCTIONS
Before you start programming the unit, move the mode selector switch (2) in to position and shortly press the RESET (7) button to clear
the existing program.
SETTING THE ACTUAL TIME AND DAY
1
After pressing the RESET (7) button, the display will look like this
.
All preprogrammed settings will be
deleted. The unit is now ready to be programmed.
2
You can set the actual time by pressing the [h] hours(6) and [m] minutes (5) , 24 hr display!
3
You can set the actual day by pressing the [1…7] button(8), (Mon=1, Tue=2, We=3…..).
1
st
Step
Move the mode selector switch (2) into position
.
The clock has 16 points: 8 x ON (OPEN the valve) and 8 x OFF (CLOSE the valve).
All odd (1,3,5 etc.) switch points open the valve, all even (2,4,6 etc.) switch points closes the valve. The switch points are numbered from 1
to 16. When programming the unit, the
symbol will display when setting a valve open cycle.
When the following display appears
you can enter the first valve open cycle.
2
nd
Step
Enter the time you would like the valve to open by means of pressing the (h)hours (6) and
(m)minute (5) buttons.
3
rd
Step
Set the day of the week when the valve should OPEN (by pressing [1…7]) (8).
- set the day (8)
(Mon=1, Tue=2, We=3…..)
- Form time blocks Mon-Fri (1/2/3/4/5)
Mon-Sat
(1/2/3/4/5/6)
Mon-Sun
(1/2/3/4/5/6/7)
The day must be set otherwise the switching point will not be activated.
4
th
Step
By pressing the [
] (9)key, you save the switching point data and go on to the next switching
point (CLOSE).
The display will show
.
You can now set the time and day for closing the valve.
By pressing the [
] (9)key, you save the switching point data and go on to the next switching point
(OPEN).
5
th
Step
To set the next OPEN and CLOSE cycle, please refer to step 3, 4 and 5.
To go to the next day, you must complete the 16 switching points (leave the unused switching points at
the value 0:00 by simply pressing the [
] (9)key until the display shows
(3)).
Then select the next day and continue programming as described under step 3, 4 and 5.
6
th
Step
After you have finished programming the unit, move the mode selector switch 2 in to position RUN
And move mode selector switch (1) in to position AUTO.
The unit will now operate fully automatically.
CHOOSING THE CORRECT WORKING MODE (Mode selector switch 1):
AUTO
Unit will work by means of its program (also when using the remote switching feature)
I
Unit will OPEN valve permanently (i.e. after hours work shift)
O
Unit will CLOSE valve permanently (i.e. holiday factory shutdown)
PROGRAM OVERRIDE BUTTON
[
]
(4)
By pressing the [
] (4) button you will override the program for this day (meaning the valve will be closed from the time you press the
[
] (4) button , until 24:00 the same day. When in override mode the
(4) symbol will be displayed, after which the
symbol
will be displayed indicating the program mode per day.