Jolywood HD108N Installation Manual Download Page 6

3.1.6  Stack no more than 2 layers

3.2  Unloading Instructions

3.2.1

3.4 

Storge

3.3  Secondary Transportation 

          and Precautions

3.3.1 

3.2.2

3.3.2

2

6

Jolywood (Taizhou) Solar Technology Co.,Ltd.

Kaiyang Rd., Jiangyan Economic Development zone, Taizhou City, Jiangsu Province, P. R. China

www.jolywood.cn

 [email protected]

 +86-523-8061 2361

Installation Manual

 - Jolywood N-type Mono-crystalline Double Glass Module

When unloading modules from vehicle, less than 
2  lots  package  could  be  lifted  each  time  with  a 
reasonable fixture. Before lifting, ensure that the 
trays and cartons undamaged, the hoisting ropes 
are durable. When the hoisting is near the ground, 
two  men  put  carton  gently  on  a  relative  flat 
position. Using a forklift to remove modules from 
the truck, unloaded modules should be placed on 
a level surface. The depth of forklift forks into the 
pallet  shall  not  be  less  than  3/4  of  the  pallet 
length.

When modules is temporarily stored in a project 
site,  modules  should  be  placed  in  a  dry  and 
ventilated  place.  Do  not  stack  modules  at  a 
project site. Cover modules with a tarpaulin, the 
tarpaulin should be fixed by a curtain or mesh belt 
to protect modules from moisture and rain.

Please store the modules in a dry and ventilated 
environment  and  place  the  modules  on  a 
relatively flat ground to avoid package damage or 
dumping due to ground deformation or collapse. 
Storage 

requirements: 

humidity 

<85%, 

temperature range -40 ℃ -50 ℃.

If the modules need long-distance transportation 
or long-term storage, do not remove the original 
packaging,  and  keep  the  wrapping  film  and 
packaging carton intact.

If the module would be transported for a too long 
distance or stored for a long period, it is forbidden 
to remove the original package. Modules 

packaged  with  original  package  could  be 
transported  by  land,  sea  or  air.  During 
transportation, fixing the package to the transport 
platform  to  ensure  it  would  not  be  tumbled. 
Taking land transportation as an example. When 
transported with truck, stacking up should be less 
than  two  layers,  it  is  forbidden  to  cut  the 
packaging  belts  of  packages.  There  shall  be  no 
gap between pallets or between pallets and truck 
supports. If there is a gap, it must be filled with 
fillers  (inflatable  bags,  etc.)  to  prevent  modules 
from tilting and shaking during transportation.

It  is  forbidden  to  remove  the  original  package 
when modules transported at a project site. One 
pallet  transported  each  time  is  required.  During 
transportation,  fixing  package  to  the  transport 
platform to ensure that the package would not be 
tumbled.  Do  not  use  tricycle  to  transport 
modules.  Do  not  handle  modules  with  rope 
during transportation, and it is forbidden to carry 
or drag modules through the wires or junction box 
of the modules.

Summary of Contents for HD108N

Page 1: ...INSTALLATION MANUAL Jolywood N type Mono crystalline Double Glass Module M10 Double glass module HD108N P All rights reserved Jolywood Taizhou Solar Technology Co Ltd ...

Page 2: ...tallation Installation Safety Mechanical installation and precautions Framed Bifacial Double Glass Modules installation with clamps Grounding Electrical installation Wiring Fuse Maintenance for PV Modules Module Visual Inspection and Replacement Connector and Cable Inspection Cleaning Water quality requirements Module Inspection after Cleaning Troubleshooting Technical Issues or Claims Framed Bifa...

Page 3: ...sional knowledge and the system must be installed and maintained by qualified person with professional knowledge Please store this guide in a safe place for future reference maintenance which would also be useful when selling or disposing of the modules The module installer must inform the end customer or consumer of the above matters accordingly Jolywood reserves the right to change this installat...

Page 4: ...by qualified person with professional knowledge Persons without authorization and relevant training should not touch modules and approach the installation area or module storage area Do not connect the positive terminal of a single module to the positive terminal of another module Please make sure that the polarity of each module or module string is not opposite to other modules or module strings P...

Page 5: ...directly on the module during transportation Improper transportation or installation also may damage module which is excluded from the warranty Do not stand climb walk or jump on unpacked pallets of modules Always work under a dry environment ensure that all modules and electrical contacts are clean and dry before installation If it is necessary to store the modules outdoors for a certain period o...

Page 6: ... on a relatively flat ground to avoid package damage or dumping due to ground deformation or collapse Storage requirements humidity 85 temperature range 40 50 If the modules need long distance transportation or long term storage do not remove the original packaging and keep the wrapping film and packaging carton intact If the module would be transported for a too long distance or stored for a long p...

Page 7: ... fixed The ground needs to be flat enough to ensure package could be placed horizontally and stably Supportive tool should be used when disassembling the carton to prevent the modules from falling down 4 1 3 Wear protective gloves during unpacking to avoid injury and fingerprints on the glass surface 4 1 4 Module information could be queried from outer package please read it carefully before unpackin...

Page 8: ... during installation Do not open the electrical connection or pull out the connector while the circuit is under load Do not touch the modules during installation unless necessary Glass surfaces and brackets may have high temperature which might lead to the risk of hazards of burns and electric shock The modules produced by Jolywood could installed landscape or portrait the influence of shading effec...

Page 9: ...fire 5 1 9 The application level of module produced by Jolywood is Class A modules with different color should be avoided from installed in the same array or roof Mounted with 4 clamps along long frame C shaped steel parallel to the long frame Edge Clamp width 40 50mm height 30mm A 350 30mm maximum test load front 2400Pa back 2400Pa snow and wind loads depends on the way of module installed The mech...

Page 10: ... 350 30mm maximum test load front 5400Pa back 2400Pa Mounted with 4 clamps along short frame C shaped steel parallel to the short frame Edge Clamp width 40 50mm height 30mm A 250 30mm maximum test load front 1200Pa back 1200Pa JW HD108N P JW HD108N P Mounted with 4 clamps along short frame Edge Clamp width 40 50mm height 30mm A 50 100mm maximum test load front 1200Pa back 1200Pa JW HD108N P Mounte...

Page 11: ...he screw faces the frame mounting holes D The outer flat washer needs to use M8 A2 70 a stainless steel SUS304 flat washer with an outer diameter of 20 2 mm and a thickness of 1 1 1 2 mm the corresponding stainless steel spring washer thickness is 2 0 0 2mm B The modules are fastened at 8 points according to load requirements or installation requirements Four points on the long side C The tensile st...

Page 12: ...lectrical contact is formed by penetrating the anodized coating of the aluminum frame and tightening the ground screw together with the star washer to an appropriate torque of 3 7N m A properly sized ground wire 4 16mm2 copper core wire should be selected and mounted under the connecting bolt Place the toothed washers washers and grounding wires in turn and screw the screws into the grounding hole...

Page 13: ...age of modules shall not be higher than the maximum voltage borne by the system and factors such as the lowest expected temperature shall be considered It is recommended to calculate according to the following formula Maximum system voltage N x Voc x 1 Tcvoc x Tmin 25 Of which N represents the number of modules Voc represents the open circuit voltage of the component Tcvoc represents the temperatu...

Page 14: ...1 4 If module is damaged glass breakage or scratches on the back glass it is need to be replaced Module must be replaced with same type one Do not touch the live parts of the cables or connectors when replacing modules Use appropriate safety guards insulation tools insulated gloves insulated boots etc when handling modules a The maximum rating of the fuse connected in series is 30A and the module ...

Page 15: ...g The amount of electricity produced by a solar module is proportional to the amount of light reach on surface of it A dust covered module produces relatively lower power so it is important to keep module clean a The PV module should be cleaned under the irradiance of less than 200W m2 Avoiding cleaning water with great different temperature from air to avoid cracking Hard water needs to be softene...

Page 16: ...e any questions about technology or claims please contact the installer Please visit http www jolywood cn to contact Jolywood after sales service team Please submit the Customer Feedback Information Form at http www jolywood cn Our technical service representatives will contact you within 5 working days The required username and password will be sent via the Customer Service link Please download t...