Jolywood HD108N Installation Manual Download Page 4

2.3  operation instruction

2.3.1

3.0

Unload, Transportation and Storage

2.2.2

2.3.2

2.3.3

2.3.4

2.2.3

2.2.4

2.2.5

4

Jolywood (Taizhou) Solar Technology Co.,Ltd.

Kaiyang Rd., Jiangyan Economic Development zone, Taizhou City, Jiangsu Province, P. R. China

www.jolywood.cn

 [email protected]

 +86-523-8061 2361

Installation Manual

 - Jolywood N-type Mono-crystalline Double Glass Module

It is strictly forbidden to use modules with broken 
glass.  Damaged  modules  must  not  be  repaired. 
Contact  with  the  surface  of  the  modules  may 
cause  electric  shock.  Do  not  disassemble  the 
module or remove any part of the module. Do not 
artificially gather sunlight on these solar modules.

In order to avoid damage module, please do not 
scratch  or  hit  module,  and  do  not  use  paint  or 
adhesive on the front or back side of module. In 
order  to  ensure  insulation  performance  of 
modules  from  be  damaged,  please  avoid 
scratching, cutting the cables and connectors or 
exposed  under  the  sun  for  a  long  time.  Do  not 
drop  module  or  drop  other  things  onto  the 
module surface. Do not place any heavy or sharp 
objects on the module surface.

The  operator  of  the  system  requires  relevant 
professional knowledge, and the system must be 
installed and maintained by qualified person with 
professional  knowledge.  Persons  without 
authorization  and  relevant  training  should  not 
touch modules and approach the installation area 
or module storage area.

Do not connect the positive terminal of a single 
module  to  the  positive  terminal  of  another 
module.  Please  make  sure  that  the  polarity  of 
each module or module string is not opposite to 
other  modules  or  module  strings.  Please  make 
sure that there are no gaps between the insulating 
washers of the joint. If there are gaps between the 
insulating washers, it may cause the risk of fire or 
electric shock.

According  to  the  requirements  of  the  National 
Electrical  Code,  the  maximum  system  voltage 
should not exceed 1500V.

Please  do  not  use  water  to  extinguish  fire  when 
the power is on.

It  is  forbidden  to  climb,  step  on,  stand,  walk  or 
jump directly on the package or module.

Preventive measures and general safety rules:

Modules  should  be  stored  in  the  original  box 
before  installation.  Please  protect  the  package 
from be damaged. Transport or unpack modules

Only work in a dry environment, and only use dry 
tools.  Do  not  work  in  a  humid  environment 
without wearing any protective measures. When 
exposed  under  the  sun,  no  matter  whether 
module is connected or not, please do not directly 
touch  junction  box,  connector,  cable  or  other 
charged  objects  of  module  without  any 
protection.

Do not install module when the module is wet or 
windy.

Summary of Contents for HD108N

Page 1: ...INSTALLATION MANUAL Jolywood N type Mono crystalline Double Glass Module M10 Double glass module HD108N P All rights reserved Jolywood Taizhou Solar Technology Co Ltd ...

Page 2: ...tallation Installation Safety Mechanical installation and precautions Framed Bifacial Double Glass Modules installation with clamps Grounding Electrical installation Wiring Fuse Maintenance for PV Modules Module Visual Inspection and Replacement Connector and Cable Inspection Cleaning Water quality requirements Module Inspection after Cleaning Troubleshooting Technical Issues or Claims Framed Bifa...

Page 3: ...sional knowledge and the system must be installed and maintained by qualified person with professional knowledge Please store this guide in a safe place for future reference maintenance which would also be useful when selling or disposing of the modules The module installer must inform the end customer or consumer of the above matters accordingly Jolywood reserves the right to change this installat...

Page 4: ...by qualified person with professional knowledge Persons without authorization and relevant training should not touch modules and approach the installation area or module storage area Do not connect the positive terminal of a single module to the positive terminal of another module Please make sure that the polarity of each module or module string is not opposite to other modules or module strings P...

Page 5: ...directly on the module during transportation Improper transportation or installation also may damage module which is excluded from the warranty Do not stand climb walk or jump on unpacked pallets of modules Always work under a dry environment ensure that all modules and electrical contacts are clean and dry before installation If it is necessary to store the modules outdoors for a certain period o...

Page 6: ... on a relatively flat ground to avoid package damage or dumping due to ground deformation or collapse Storage requirements humidity 85 temperature range 40 50 If the modules need long distance transportation or long term storage do not remove the original packaging and keep the wrapping film and packaging carton intact If the module would be transported for a too long distance or stored for a long p...

Page 7: ... fixed The ground needs to be flat enough to ensure package could be placed horizontally and stably Supportive tool should be used when disassembling the carton to prevent the modules from falling down 4 1 3 Wear protective gloves during unpacking to avoid injury and fingerprints on the glass surface 4 1 4 Module information could be queried from outer package please read it carefully before unpackin...

Page 8: ... during installation Do not open the electrical connection or pull out the connector while the circuit is under load Do not touch the modules during installation unless necessary Glass surfaces and brackets may have high temperature which might lead to the risk of hazards of burns and electric shock The modules produced by Jolywood could installed landscape or portrait the influence of shading effec...

Page 9: ...fire 5 1 9 The application level of module produced by Jolywood is Class A modules with different color should be avoided from installed in the same array or roof Mounted with 4 clamps along long frame C shaped steel parallel to the long frame Edge Clamp width 40 50mm height 30mm A 350 30mm maximum test load front 2400Pa back 2400Pa snow and wind loads depends on the way of module installed The mech...

Page 10: ... 350 30mm maximum test load front 5400Pa back 2400Pa Mounted with 4 clamps along short frame C shaped steel parallel to the short frame Edge Clamp width 40 50mm height 30mm A 250 30mm maximum test load front 1200Pa back 1200Pa JW HD108N P JW HD108N P Mounted with 4 clamps along short frame Edge Clamp width 40 50mm height 30mm A 50 100mm maximum test load front 1200Pa back 1200Pa JW HD108N P Mounte...

Page 11: ...he screw faces the frame mounting holes D The outer flat washer needs to use M8 A2 70 a stainless steel SUS304 flat washer with an outer diameter of 20 2 mm and a thickness of 1 1 1 2 mm the corresponding stainless steel spring washer thickness is 2 0 0 2mm B The modules are fastened at 8 points according to load requirements or installation requirements Four points on the long side C The tensile st...

Page 12: ...lectrical contact is formed by penetrating the anodized coating of the aluminum frame and tightening the ground screw together with the star washer to an appropriate torque of 3 7N m A properly sized ground wire 4 16mm2 copper core wire should be selected and mounted under the connecting bolt Place the toothed washers washers and grounding wires in turn and screw the screws into the grounding hole...

Page 13: ...age of modules shall not be higher than the maximum voltage borne by the system and factors such as the lowest expected temperature shall be considered It is recommended to calculate according to the following formula Maximum system voltage N x Voc x 1 Tcvoc x Tmin 25 Of which N represents the number of modules Voc represents the open circuit voltage of the component Tcvoc represents the temperatu...

Page 14: ...1 4 If module is damaged glass breakage or scratches on the back glass it is need to be replaced Module must be replaced with same type one Do not touch the live parts of the cables or connectors when replacing modules Use appropriate safety guards insulation tools insulated gloves insulated boots etc when handling modules a The maximum rating of the fuse connected in series is 30A and the module ...

Page 15: ...g The amount of electricity produced by a solar module is proportional to the amount of light reach on surface of it A dust covered module produces relatively lower power so it is important to keep module clean a The PV module should be cleaned under the irradiance of less than 200W m2 Avoiding cleaning water with great different temperature from air to avoid cracking Hard water needs to be softene...

Page 16: ...e any questions about technology or claims please contact the installer Please visit http www jolywood cn to contact Jolywood after sales service team Please submit the Customer Feedback Information Form at http www jolywood cn Our technical service representatives will contact you within 5 working days The required username and password will be sent via the Customer Service link Please download t...

Reviews: