30
3
4
6
1
2
Menu 10
XXX = SET
YYY =ADJUST-
Menu to adjust the load PELLET settings and combustion fan
speed
ADJUSTMENT SETTINGS:
1. button 4, press button 6 to reach the SET ADJUST- page, press
button 4 to confirm
2. on page 1, ADJUST PELLET, press button 4 to enter, then press button 1 or 2 to increase or decrease the PELLET load
3. press button 6 to go to the ADJUST CHIMNEY page
4. press button 1 or 2 to adjust the value
5. press button 3 to exit, press repeatedly to return to the home page
ADJUST PELLET: use this setting when there is a change in the type of pellet used during the first start-up, i.e. when the Assistance
Technician calibrated the operational settings. This value should be increased if the pellets are much smaller than the previous version
or has a lower heat efficiency, and vice versa.
ADJUST CHIMNEY: use this setting when the draught conditions change. Increase in cases of weak draught and vice versa.
WARNING:
Jolly-Mec declines all liability regarding incorrect adjustments and setting that could cause the stove to malfunction.
3
4
6
Menu 11
XXX = READ
YYY = MEMORY
Displays some operating settings stored in the memory
READ MEMORY DISPLAY:
1. button 4, press button 6 to reach the READ MEMORY page,
press button 4 to enter
2. page 1 displays the total operating hours
3. press button 6 to go to page 2 which displays the partial opera-
ting hours; i.e. the operating hours since the last extraordinary
maintenance work
Menu 12
XXX
YYY
3
4
6
1
2
5
4. press button 6, to go to page 3 which displays the number of start-ups
5. press button 6 to go to page 4 which displays the partial resets
6. press button 6 to go to page 5 which displays the alarms memory log. Each alarm page shows how many times it was triggered
and the date of the most recent event.
7. press button 6 to move from one alarm page to the next
8. move on by pressing button 6. From page 10 to 13 the name, the manufacturing date, the lot and the serial number of the product
are displayed
9. press button 3 to exit at any time, press repeatedly to return to the home page
2.
press button 1 or 2 to set the operating mode to AUTO, MANUAL or SEMIAUTO MODE and press button 4 to confirm
3. on page 2 press button 1 or 2 to set the V2 fan speed (RH ducting); press button 5 or 6 to change the SET V2 ambient parameter
4. go to the next page and enter the same settings for the V3 ducting (LH ducting)
5. press button 3 to exit, press repeatedly to return to the home page.
Menu 12
XXX = SET
YYY = CANALIZ-
Ducting operating mode settings (if foreseen)
DUCTING SETTINGS:
1. button 4, press button 6 to reach the SET CANALIZ- page,
press button 4 to enter
Menu 10
XXX
YYY
Menu 11
XXX
YYY