Jolly Mec FOGHET EVO Installation, Use And Maintenance Manual Download Page 8

8

•  In alarm status for failed start up, do not try to restart the stove until the firebox has been thoroughly cleaned
•  The appliance must always be started up with the firebox empty, without pellets and without unburned fuel from previous 

use.

•  Do not attempt to ignite the fuel with inflammable liquids or solids; the stove must ignite automatically via the electrical 

components installed onboard.

•  Do not load pellets manually into the firebox before or whilst the appliance is running.
• 

Keep the ventilation grids in the area the appliance is installed in clean conditions.

• 

Never load any fuel other than pellets into the stove storage hopper. Corn, nuts or other combustible materials must not be 

used as fuel for the appliance.

•  Check and periodically clean the fume exhaust pipe, from the appliance to the flue (Union).
• 

It is strictly prohibited to start up the product with the combustion chamber door open or allow it to run with the glass broken

• 

The user should contact an authorised JOLLY-MEC Technical Assistance Centre if any operating problems persist.

•  Never try to start the device using ethyl alcohol or other flammable liquids.

 

02.3 

SAFETY REGULATIONS FOR EXTRAORDINARY MAINTENANCE AND INSTALLATION

• 

The user and/or owner of the product is required, in accordance with the laws in force, to assign the installation and 

maintenance to qualified and specialised operators, and acknowledge the risks and hazards should they fail to observe 

this requirement.

• 

The installation of the heat generator and the relative combustion product exhaustion system, the electrical connections, 

the commissioning and extraordinary maintenance MUST always be performed by Qualified and/or Licensed Professional 

Technicians or those Authorised by the Manufacturer

• 

The product must be installed in accordance with the laws and standards in force in the State, Region or Area in which 

the machine is installed.

• 

Installation in bedrooms, rooms with a volume below 15 m

3

 or with explosive atmospheres is strictly prohibited.

• 

The system installer MUST issue a Declaration of compliance for the work performed after commissioning the system, 

in accordance with the laws in force related to system safety standards.

• 

The installation technician must inform the user on safe equipment use.

• 

The installation operator is responsible for the installation and is therefore required to perform the work to top workmanship 

standards.

•  The appliance must be connected to a combustion product exhaustion flue built in accordance with applicable 

standards and certified with a declaration of compliance.

•  The installation technician is in charge of installation and must check emissions following first installation.
• 

Should any installation defects arise during commissioning, the Authorised Jolly-Mec Technician can refuse to endorse 

use of the product for safety reasons and submit a written Servicing Report to the User informing him that he and the 

Installation operator shall be jointly liable for any damage to persons, animals or things if used.

•  Before installing the machine, the customer and installation operator must ensure that the flooring on which it will be 

positioned is suitably levelled and can support the weight (see 

CHAP.06 - TECHNICAL DATA

). IIf there is any doubt 

on the solidity of the flooring, it is essential to have a Structural Engineer verify relative installation feasibility.

•  Only specialised and qualified personnel may work or carry out checks inside the machine, complying with safety 

regulations.

• 

Prior to installation, the user and installer are obliged to check that the mains electrical supply to which the machine will be 

connected, corresponds to the voltage on the identification plate (see 

CHAP.05.2 - PRODUCT IDENTIFICATION

), 

check that the system is sized so as to bear the maximum load required of the product, and also that it is equipped with 

Summary of Contents for FOGHET EVO

Page 1: ...SM098 EN REV01 2014_09 fireplace FOGHET EVO water INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Wood operated water fireplace FOGHET EVO...

Page 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Page 3: ...E MACHINE 11 CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 16 06 4 DIMENSI...

Page 4: ...appropriate This manual cannot be given to third parties for perusal without the written permission of Jolly Mec Caminetti S p A The technical directions for installation contained in this manual sho...

Page 5: ...EN 60335 1 Safety of household electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations...

Page 6: ...commended requirements NOTE 01 4 USE AND STORING OF THE INSTALLATION AND MAINTENANCE MANUAL Recipients of the manual The use and installation manual is addressed to users responsible for the installat...

Page 7: ...observe this requirement Use of this product is not permitted for children persons with acknowledged reduced psycho physical and sensory abilities and persons who lack experience in using such machine...

Page 8: ...in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly prohibited The system installe...

Page 9: ...o account Removal or tampering with the protection and safety devices can be only be done voluntarily and may cause serious injury to people Replace the safety signals when they become illegible or co...

Page 10: ...NSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manual and must wear work...

Page 11: ...e packaging into the environment but take it to waste disposal centres for recycling All packaging can be recycled as it consists of wood polyethylene film polystyrene and cardboard WARNING PROTECT TH...

Page 12: ...that manages the fireplace when operating on wood The control unit allows management of parallel boiler a thermoboiler or thermal cell and the circulation pump for the heating system When running on w...

Page 13: ...g ans Fluid Puissance c d e au fluide Potencia cedida al fluido Rendimento Efficiency Wirkungsgrad Rendement Rendimiento Potenza elettrica nominale Rated electrical power Elektr Leistungsaufnahme Puis...

Page 14: ...nimum diam 150 e o 200 mm Maximum working pressure 2 bar Heating pumpe head 1m3 h 6 m Max capacity of heating system pump 5 m3 h Max T smoke by wood 300 C Med T smoke by wood 189 C CO 13 O2 wood 1245...

Page 15: ...ver Fir 4 5 Red Fir 4 4 Birch Tree 4 3 Hornbeam 3 9 Beech 4 0 Ash 4 2 Poplar 4 1 Oak 4 2 Locust Robinia 4 1 Durmast 4 2 SOME TIPS AND INFORMATION The best fuel is air dried untreated wood with a humid...

Page 16: ...the following parts Assembly use and maintenance manual Boiler body complete with tested hydraulic kit Control panel with electronic controller Cast iron grille for wood burning Smoke damper with knob...

Page 17: ...materials via an air space or suitable insulation must have an internal section which is preferably circular square or rectangular sections must have rounded corners with a radius of no less than 20 m...

Page 18: ...th the distances foreseen by UNI 10683 Flue assembly phase Once the flue got insert in the foreseen connection fill the gap with the sealing in outfit Fig 3 The Foghet Evo fume exhaust has a diameter...

Page 19: ...eaned smoking pipes and chimney easely reached and cleaned too please install accordingly The expansion vase has to be correctly calculated therefore check if the one available is big enought for your...

Page 20: ...ached and cleaned too please install accordingly The expansion vase has to be correctly calculated therefore check if the one available is big enought for your installation if this is not the case it...

Page 21: ...e flooring ceiling and walls of the home in the vicinity of the fireplace must be protected to prevent overheating Insulating panels must be overlapped to avoid leaking The sizes and types of insulati...

Page 22: ...mostat optional 13 Plumbing kit 14 Inspection door for Hydraulic kit REQUIRED refer to the ATTENTION box for details on dimensions 15 Damper control 16 Lifting hook It is compulsory to foresee inspect...

Page 23: ...cks B Fireplace Water Probe C I2 Probe D common for I3 Probe E I3 Probe Water Pressure Probe F 5V Power for Water Pressure Probe Terminal OUTLETS correspondence 1 O3 auxiliary Outlet Neutral 2 O1 Fire...

Page 24: ...eturn flow from the system filling and emptying of hot water mandatory connection 10 Venting valve Complete Hydraulic kit The complete hydraulic kit consists of the following components 1 Cold water i...

Page 25: ...l be connected to For medium large systems a heat technician should inspect and calculate the needs of the rooms to be heated according to current regulations WARNING 1 Cold water inlet for cooling se...

Page 26: ...in a cardboard box containing the following components Code Description Values UM QUA LEGNA IDRO Electronic Card with Display H 73 x L 120 x S 50 mm SCAT INC 503 Back Box H 73 x L 110 x S 50 mm SONDA...

Page 27: ...message accordingly Signal reporting the anti lock and or anti freeze cycle the icon is flashing Signal reporting the activation of O2 Outlet In Plant Scheme 2 the icon turns ON when the DHW Pump is...

Page 28: ...gulated by the quantity of combustion air COMBUSTION For this type of functioning except when loading the fireplace door must always be closed to ensure correct combustion and to prevent combustion fu...

Page 29: ...ion and it can be easily removed to clean the flue by extracting the rod see Fig 1 Step 2 Secure the adjustment unit with respective knob and position indicator to the hood with the screws and plugs s...

Page 30: ...following poor flue draught clean the flue or check that the flue dimensions conform to requirements Insufficient combustion air excessive amount of wood during start up and when functioning Never li...

Page 31: ...ew days during operation with pellets check the burn pot to determine how often it needs cleaning Before any cleaning always turn off the main switch and make sure the fireplace is cold 1 Opening the...

Page 32: ...aping from the door a open the fumes deflector b Release the fumes deflector FIG 8 and FIG 9 c Use a tool to shake the turboclean in the flue If very dirty remove the turboclean lifting it by a few ce...

Page 33: ...lised technician once a year in autumn before lighting the fireplace 8 Pressure relief valves The safety valve 1 needs venting annually 9 Pressure reducer with pressure gauge For annual cleaning of th...

Page 34: ...ace The boiler must be clean as new Check that the fireplace is completely cool Replace the various components following the dismounting instructions in the reverse order Open valve for water inlet an...

Page 35: ...rwell by installing a door There are other appliances that use room air creating low pressure Use the fireplace when the other appliances are off excluded of the type C according to UNI 10683 Excessiv...

Page 36: ...esponding parameter in Menu SET TECHNIC is set as PROBE Check the electrical connection of the probe if it has to be changed call the competent CAT for intervention AL7 ICE The device water temperatur...

Page 37: ...37 ENGLISH NOTES...

Page 38: ...38...

Page 39: ...39 ENGLISH...

Page 40: ...SM098 EN REV01 2014_09 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...