CHAP.06 TECHNICAL DATA
06.1 HOMOLOGATION
Technical specifications resulting from laboratory tests conducted according to EN 13229 test methods at the CERTIFICATION institute.
Description
Nominal value
UM
Burned power (by wood)
18,91
kW
Consumption at max power (by wood)
4,1
kg/h
Max power give to the environment (by wood)
5,85
kW
Thermal rated output (by wood)
15,89
kW
Power given to fluid (by wood)
10,04
kW
Efficiency (by wood)
84
%
Max. heated area depending the kind of house
130-170-270
m
2
Surface exchange
1,7
m
2
Nominal voltage/frequency
230/50
V/Hz
Electrilcal absorption
50
W
Boiler weight
245
kg
Draft
12+/-2
Pa
Fume exhaust minimum diam.
150 e/o <200
mm
Maximum working pressure
2
bar
Heating pumpe head (@ 1m
3
/h)
6
m
Max. capacity of heating system pump
5
m
3
/h
Max T smoke (by wood)
300
°C
Med T smoke (by wood)
189
°C
CO (13% O
2
) (wood)
1245
mg/m
3
CO
2
(wood)
8,8
%
Smoke volume (by wood)
14,9
g/s
Dusts
(13% O
2
) (by wood)
38,9
mg/m
3
Max load (wood)
3,1
kg
Inflammable goods distance
200 side - 700 front
mm
Note:
This device can not be used with shared flues.
Recommended fuels:
for a list of recommended fuels, please see
CHAP.06.2 – RECOMMENDED FUELS
To achieve best operational results, it may be necessary to change the default factory settings on the control unit
during the “first start-up” commissioning phase. These operations must only be performed by the relative Technical
Assistance Centre
(CAT), being the only operators authorised to complete the first start-up activities