XXX = SET
YYY =ADJUST-
Menu to adjust the load PELLET settings and combustion fan
speed
ADJUSTMENT SETTINGS:
1. button 4, press button 6 to reach the SET ADJUST- page, press
button 4 to confirm
2. on page 1, ADJUST PELLET, press button 4 to enter, then press button 1 or 2 to increase or decrease the PELLET load
3. press button 6 to go to the ADJUST CHIMNEY page
4.
press button 4 to confirm and enter, press button 1 or 2 to adjust the value
5. press button 3 to exit, press repeatedly to return to the home page
ADJUST PELLET: use this setting when there is a change in the type of pellet used during the first start-up, i.e. when the Assistance
Technician calibrated the operational settings. This value should be increased if the pellets are much smaller than the previous version
or has a lower heat efficiency, and vice versa.
ADJUST CHIMNEY: use this setting when the draught conditions change. Increase in cases of weak draught and vice versa.
WARNING:
Jolly-Mec declines all liability regarding incorrect adjustments and setting that could cause the stove to malfunction.
Menu 08
XXX
YYY
5
3
4
6
Menu 08
XXX = STATE
YYY = STOVE
Menu 8 consists of various pages that display information on
the stove conditions.
VIEWING STOVE STATUS:
1. button 4, press button 6 to reach the STATE STOVE page,
press button 4 to confirm.
2.
the first page displays:
a. fume temperature, first row
b. fume fan speed and output level, second row
c. pellet load, third row
d. phase in progress, fourth row
3. press button 6 to change page
4. information for the assistance technician is provided from page 2 to page 8. Press Button 5 to go to page 8.
5. press button
3
to exit, press repeatedly to return to the home page.
Menu 09
XXX = TECHNIC
YYY = SETTINGS
Password protected Menu reserved to the specialised Technical