24
Example
of display message with the
stove in FLAME STABILI-
SATION MODE
.
xxx
= FLAME
YYY = ON
Stove running mode:
The WORK message informs the user that the stove is in “OPERATING MODE” i.e. it has reached the preset heating output level. The
stove operating level is set using buttons 5 or 6 and increasing or decreasing the value displayed on the first row with the same status.
There are 5 heat output levels.
The ambient temperature can be SET pressing buttons 1 or 2, which are also used to adjust the temperature to the desired value. The
stove remains in operating mode; i.e. at the heat output level, until the set ambient temperature is exceeded by 0.5°C, a condition required
to trigger the ECO function. To restart the heating mode, the ambient temperature must decrease to 1.0°C below the SET temperature.
The fan speed for the hot air exhausted through the grid depends on the output levels; the higher the output level, the faster the air will
be pumped through the front grid.
Example
of display message with the
stove in RUNNING
mode.
XXX = WORK
Example
of display message with the
stove in ECO mode
.
xxx
= ECO
YYY = MODULAT-
Example
of display message when adjusting the
AMBIENT TEM-
PERATURE SETTING.
xxx
= SET TEMP
YYY = ROOM
Example
of display message when adjusting the
HEAT OUTPUT
SETTING.
xxx
= SET
YYY = POWER
10:30
25°C P3
XXX
YYY
10:30
25°C P3
XXX
10:30
25°C P3
XXX
21.0 °C
XXX
YYY
03
XXX
YYY
SIL
XXX
YYY
Silent mode setting
When the Silent mode is activated, the product is set to work as
silent as possible.
To set the SILENT mode, press key
5
on the main page to imme-
diately open the relevant section. Using keys
5
and
6
, set the mode.
After selecting SIL, press key
3
to return to the main page.
xxx
= SET
YYY = POWER