Jola RK 1/K Variant Ex Series Installation, Operating And Maintenance Instructions Download Page 6

Installation, Operating and Maintenance  

 

 

6/8 

Instructions for Jola external-mounting limit switches 
RK 1/K/…/Variant ./Ex-..   

 

 

 

21.04.2018

 

 

5.  Installation of the external-mounting li

mit switches RK 1/K/…/Variant ./Ex-.. 

 

The mounting of the 

RK 1/K/…/Variant ./Ex-.. limit switches has to be effected via a 

through hole situated in the middle of the body of the switch.

 

 

Through this hole, the limit switch has to be mounted on a 

horizontal metallic shaft

 of 

the customer’s device which permits a rotation of max. +/- 180°. The rotation of the 
shaft causes the switching. In order to prevent an incorrect functioning of the limit 
switch and a cable break, a sufficient cable length must be left.  
 
After the limit switch has been set on the shaft, it has to be fixed by the screw placed 
inside the body of the switch.

 

 
The external-

mounting limit switches RK 1/K/…/Variant ./Ex-.. are not suitable to 

be used on rotating shafts. 
 
When mounting the external-mounting limit switch, take care to ensure that the 
switch and in particular the cable are not damaged by sharp edges and objects. 
 
 
 

The horizontal metallic shaft has to be connected to the potential 

equalisation system. 

Summary of Contents for RK 1/K Variant Ex Series

Page 1: ...These Installation Operating and Maintenance Instructions must always be handed over to the fitter operator service personnel of our products together with all other user documentation and informatio...

Page 2: ...ia IIC T6 Ga or II 2 G Ex ia IIC T6 Gb Tamb 20 C to 60 C INERIS 12ATEX0059 are binary contact devices for use in underground areas in mines as well as in above ground areas of mines which could be at...

Page 3: ...hole situated in the middle of the body of the switch Through this hole the limit switch has to be mounted on a horizontal shaft of the customer s device which permits a rotation of max 180 The rotat...

Page 4: ...or the external mounting limit switches RK 1 K Variant Ex Sensor type Type designation Li Ci Each external mounting limit switch RK 1 K Variant Ex 1 H per meter connecting cable 200 pF per meter conne...

Page 5: ...itch and following all instructions contained therein The qualified specialist personnel must ensure that they are familiar with all valid standards regulations local requirements and specific conditi...

Page 6: ...mits a rotation of max 180 The rotation of the shaft causes the switching In order to prevent an incorrect functioning of the limit switch and a cable break a sufficient cable length must be left Afte...

Page 7: ...em and not to a potential earth 7 Start up Prior to start up you must re check the mounting position the mechanical fastening and the electrical connection In particular you must check once again that...

Page 8: ...witch is installed as a safety element within a system it must always be inspected and checked at intervals to be agreed with the local supervisory authorities Prior to all maintenance work the qualif...

Reviews: