28
©2015 Johnson Level & Tool
5. Press the ENTER button on the remote control to accept the
calibration value, noting that the Y LED goes “OFF”.
6. After calibration is completed, make sure to power off the unit
and then power on again to activate the calibration.
Z-Axis Check/Calibration
1. Place the unit on a level surface with the Y direction facing the
far target.
2. Mark the wall where the laser hits.
3. Turn the laser “OFF” then “ON” again.
4. Place the unit so the Z axis is facing the far target.
5. Measure the difference between the line and the dot.
6. It should be between 3 3/8" and 3-1/2". If it is less the 3 3/8"
or greater than 3 1/2", place unit in calibration mode.
7. Press UP arrow and DOWN arrow buttons conversely to adjust
the laser height to coincide with the zero position of the target.
8. Press the ENTER button on the remote control to accept the
calibration value, noting that the Y LED goes “OFF”.
9. After calibration is completed, make sure to power off the unit
and then power on again to activate the calibration.
8489H-All_Manuals 11/18/14 11:50 AM Page 28