background image

Digital Angle Locator

Model No.  40-6064

Instruction Manual

Congratulations on your choice of this Digital Angle Locator. We 
suggest you read this instruction manual thoroughly before using the
instrument. Save this instruction manual for future use.

Features and Functions 

• Digitally displays angle
• Angle measurements in degrees
• Working range of angle measurement 

0 to 222º

• Automatic shut-off
• Hold function to freeze measurement

Safety Instructions

Please read and understand all of the following
instructions, prior to using this tool.

Location of Parts/Components

Angle level arm

Battery
compartment

Vial for
horizontal
leveling

Vial for
vertical
leveling

Base arm

Hold Key

Miter key

On/Off key

Battery Installation

• To open the battery cover, unscrew the 

end cap then pull out

• Insert the 9V battery paying attention to 

the polarity, put back the end cap and 
screws

• Power on the instrument

Note:

Used (discharged) batteries are hazardous
waste and should be disposed of properly. Take
out the batteries if the instrument is not going
to be used for a long time.

Using the Product

On/Off Key

Power on and off the instrument by pressing
this key.

Hold Key

The angle readings change in accordance with
the change of the angle measurement. Press
the key to enter into the “hold” mode. The
measured angle reading will be held. Pressing
the key again will stop the “hold” mode and
measured value will change with the movement
of the angle level arm.

Miter Key

The key switches the measured angle and con-
verts it to the miter cut angle. This measure-
ment is the angle that needs to be set in the
miter saw to create the correct cut angle.

Automatic Shut-off

This instrument will shut-off automatically if no
operation is received within five minutes.

Measuring Angles

Position the angle level arm and the base arm
plane against the edges to be measured. The
displayed reading corresponds with the z angle
between the angle level arm and the base arm.

The displayed reading can be retained in the
display by pressing the 

HOLD

key.

When the hold key is pressed,

“HOLD”

is 

indicated in the display. The measured angle
reading will be held (even when the legs are
moved in relation to each other) until the 

HOLD

key is pressed again.

a work piece, pay attention that the angle level
arm and base don’t move. After pressing the

HOLD

key, which store the measured angle, the

user can now activate the 

MITER

key. By

pressing the miter key, the Angle Finder is tak-
ing the measured angle and
converting it to the correct
miter cut angle. This 
measurement is the angle 
that needs to be set in the 
miter saw to create the 
correct cut angle.

Transferring angle to miter angles

When directly projecting a measured angle onto 

Technical Specifications

Working Range Angle

0º - 222º

Accuracy Angle

±0.5º (9mm/m)

Power Supply

1 9V battery

Battery Life

Approx. battery life 
50 hours 
continuous use

Dimensions arm to

17.72" 

arm length

(450mm)

Weight

1.1 lbs
(0.5 Kg)

Working temperature

32ºF to 122ºF
(0ºC to -50ºC)

Automatic Shut-off

After 5 min. approx.

Lifetime Warranty

Johnson Level & Tool warrants this product to be
free from defects in material or workmanship for
the normal life of this product. Product abuse
voids warranty. At its sole option, Johnson will
repair or replace this product if it fails to conform
to this warranty under normal use and service.
Johnson’s liability is expressly limited to the repair
or replacement of the defective product.

Note:

The user is responsible for the proper use and care of the
product.

For further assistance, or if you experience problems with
this product that are not addressed in this instruction 
manual, please contact our Customer Service Department.

In the U.S., please call 800-563-8553.
In Canada, please call 800-346-6682.

Localizador de Ángulo Digital

Modelo N.° 40-6064

Manual de Instrucciones

Felicitaciones por elegir este Localizador de Ángulo Digital. Le
sugerimos que lea este manual de instrucciones cuidadosamente antes
de usar el instrumento. Guarde este manual de instrucciones para
poder consultarlo en el futuro.

Características y Funciones 

• Muestra el ángulo de forma digital
• Mediciones de ángulos en grados
• Rango operativo de medición angular de

0 a 222º

• Apagado automático
• Función de suspensión para congelar la   

medición

Instrucciones de Seguridad

Lea y comprenda todas las instrucciones a 
continuación, antes de utilizar esta herramienta.

Brazo del nivel de ángulo

Compartimento
de las baterías

El frasco para
nivelar horizontal

Ampolla para
nivelación
vertical

Brazo base

Botón de suspensión

Botón para
ingletes

Botón de
Encendido
y Apagado

Instalación de las Baterías

• Para abrir la cubierta de las baterías,

desajuste la cubierta protectora para 
extremos y luego extráigala

• Inserte la batería de 9V prestando atención 

a la polaridad, vuelva a colocar la cubierta 
protectora para extremos y los tornillos

• Encienda el instrumento

Nota:

Las baterías usadas (descargadas) son residuos
peligrosos y se deben desechar de forma ade-
cuada. Extraiga las baterías si el instrumento no
se va a utilizar durante un tiempo prolongado.

Cómo Utilizar el Producto

Botón de Encendido y Apagado

Para encender o apagar el instrumento presione
este botón.

Ubicación de las Piezas y
Componentes

Reviews: