21.  ANA TEST 

View the control level for each of the analog inputs.

 

 

The analog voltage level for the 4 analog inputs can be tested and viewed as a 

percentage or hexadecimal value. The level displayed is proportional to the 0-10VDC 

analog input where 5VDC is 50%.

 

 

Press EXECUTE to enter the menu and activate analog test mode.

 

AI>01=00 

Displays the active analog input (AI>01) and the level (00).

 

AI>04=00 

Press MENU (

     

) to select the desired analog input to test.

 

AI>04=FL 

Displays the analog input level from off (00) to full-on (FL).

 

 

Press ESCAPE or RESET to exit the menu.

22.  ANA FLTR 

Apply a noise filter on the analog inputs of up to 1 Volt.

 

 

High frequency noise can sometimes be induced into the analog input lines. The 

analog filter is set in 1% increments where each percent (%) represents 0.1 Volts for 

a maximum filter level of 1 Volt, or 10%. For example, when the analog filter level is 

set at 5% (LEV:05%) all analog input levels at or below 0.5 Volts is ignored or filtered out.

 

LEV:00% 

Displays the filter level (00%) in percent.

 

LEV:00%< 

Press EXECUTE to enter the menu and adjust the analog filter level.

 

LEV:10%< 

Press MENU (

     

) to select the desired filter level.

 

 

Press ESCAPE to exit the menu and save the desired analog filter level.

 

 

Press RESET to exit the menu without saving.

 

 

The menu will automatically timeout after 2 minutes of inactivity and save.

23.  ANA BLOC 

Enable or disable the analog inputs when DMX is being received.

 

 

When analog blocking (ANA BLOC) is enabled the analog inputs will be ignored when 

DMX is online. When analog blocking is disabled the analog inputs will be merged/

combined with the DMX inputs and functions in a highest-takes-precedence (HTP) 

mode of operation.

 

ENABLED 

Press EXECUTE to toggle analog blocking from ENABLED to DISABLED.

 

DISABLED 

Press EXECUTE to toggle analog blocking from DISABLED to ENABLED.

 

 

Any change in the configuration is automatically saved.

24. STANDBY 

Enable or disable the power savings standby mode.

 

 

When standby mode is enabled the microcontroller goes to sleep within 5 seconds 

of inactivity on the control inputs. The microcontroller wakes up again when a 

programming switch is pressed or when control is sensed on the control inputs. Note 

that there is a delay of 150 milliseconds for the microcontroller to wake up and restart 

normal run mode.

 

ENABLED 

Press EXECUTE to toggle standby mode from ENABLED to DISABLED.

 

DISABLED 

Press EXECUTE to toggle standby mode from DISABLED to ENABLED.

 

 

Any change in the configuration is automatically saved.

25.  TEST INC 

Set the test increment units to percent or hexadecimal.

 

 

The levels for the dimmer test (DIM TEST) and analog test (ANA TEST) features can 

be displayed as a percentage or hexadecimal value.

 

PERCENT 

Press EXECUTE to toggle test increments from PERCENT to HEX VAL.

 

HEX VAL 

Press EXECUTE to toggle test increments from HEX VAL to PERCENT.

 

 

Any change in the configuration is automatically saved.

26.  OC MODE 

Configure the input trigger parameters for the open collector output. 

 

 

The on-board open collector output is used to sink up to 100mA of current. It can be 

configured to be triggered via a selected DMX channel, analog input 4, or both. The 

open collector is triggered on at 55% control input and triggered off again at 45% 

control input. When analog and DMX (A+D) is selected to trigger the open collector 

the inputs are combine for highest takes precedence (HTP).

 

 

Press EXECUTE to enter the menu and configure the open collector output.

Summary of Contents for JS-ICON 1210

Page 1: ...User Manual JS ICON Series Dimmer Rack JS ICON 2410 JS ICON 2413 JS ICON 1220 JS ICON 1210 620 JOHNSON SYSTEMS INC www johnsonsystems com ...

Page 2: ... neither of the above can provide you with the necessary information please contact our factory via email info johnsonsystems com or phone 403 287 8003 during business hours Monday to Friday 8 00AM to 5 00PM MST Contents Warranty 2 For Technical Assistance 2 Introduction 3 Characteristics 4 Installation 5 Power Supply Connection Details 6 Ground Connection Details 8 Dimmer Output 9 Control Input O...

Page 3: ... thermal management technology produces superior cooling that is virtually silent making JS ICON the natural choice for quiet space dimming installations Exclusive lamp warming techniques extends lamp life considerably while maintaining industry leading performance Available in multiple sizes and configurations Unique power saving stand by mode reduces power consumption to less than 1 Watt Complia...

Page 4: ...Incandescent quartz lamps and electronic SCR dimmable low voltage fixtures Relay Load Type Any to maximum circuit rating Switch Type 200 rated non proprietary SCR solid state relay Choke Type High performance copper wound hybrid core toroidal magnetic filter Choke Rise Time 2400W 400µs 1560W 300µs 1200W 300µs Physical 30 x 17 x 6 8 75 cm x 43 cm x 17 cm Weight All Models approximately 66 lbs 30 Kg...

Page 5: ...O OFF I ON O OFF O OFF I ON O OFF I ON I ON O OFF I ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2002161 I ON O OFF O OFF O OFF I ON O OFF I ON O OFF I ON O OFF I ON I ON O OFF I ON O OFF I ON O OFF I ON O OFF I ON O OFF I ON O OFF I ON O OFF I ON O OFF O OFF I ON I ON O OFF O OFF I ON O OFF I ON I ON O OFF I ON O OFF I ON O OFF O OFF I ON O OFF I ON I ON O OFF I ON 1 2 3 4 5 ...

Page 6: ...l only WARNING Be sure all power connections are tightened to specification before power supply is turned on Power Supply Configurations Three Phase 120 208 VAC 3Ø 5 Wire up to 100 Amps per phase Maximum 28 8kW total Use wire size 14 to 1 0 AWG Strip insulation length to 0 65 16 5mm Torque power terminals A B C to 45 50 IN LBS 5 0 5 6 NM Below is the dimmer phasing for each JS ICON Series dimmer r...

Page 7: ...ase contact your supplier for a single phase conversion kit if required The following steps will need to be followed to convert the JS ICON dimmer rack from three phase to single phase operation 1 Remove the three phase copper bussbars by loosening all of the screws terminals use a medium sized 2 Philips or Flathead screwdriver on the left hand side of the circuit breakers 2 Insert the supplied si...

Page 8: ... 2 3 2 8 NM Models JS ICON 2410 JS ICON 2413 and JS ICON 1210 620 are supplied with 25 load circuit neutral terminals while Model JS ICON 1220 is supplied with 12 NOTE For connection use copper wire only rated for 167 F 75 C minimum Ground Connection Details Ground Input Terminal Use wire size 14 to 1 0 AWG Strip insulation length to 0 65 16 5mm Torque ground terminal to 45 50 IN LBS 5 0 5 6 NM Th...

Page 9: ...onic low voltage fixtures The dimmer outputs may be configured for non dimmed applications when switched relay controlled load outputs are required Knockouts on the top and bottom of the chassis are provided for wire conduit entry to the power terminals Load Hot Output Connection Details Load output connections are terminated via DIN rail mounted terminal blocks Models JS ICON 2410 and JS ICON 241...

Page 10: ...omplies with USITT DMX512 A ANSI E1 11 2008 Standard protocol for digital data control Recommended cable is Belden 9829 9842 Cat 5 or equivalent low capacitance twisted pair Wiring must follow a daisy chain topology Maximum of 32 receiving devices on a single DMX line Maximum cable length is 1 500 feet 455 meters For more information Google DMX or visit http old usitt org DMX512FAQ aspx NOTE Ensur...

Page 11: ... to low voltage common COM Fire Alarm Input Normally Open Terminate FIRE on J11 connector Triggers selected channels to turn on when contact switch is closed Controlled via a maintained contact switch to low voltage common COM Programmed in the F ALARM menu See page 25 for details Security Alarm Input Normally Open Terminate SCTY on J11 connector Triggers selected channels to cycle on and off at a...

Page 12: ...em LCD VIEW on page 30 for further details Programming Switches The MENU UP DOWN switches are used for navigating through the various system configuration menu items They also allow for programming of other specific parameters within a selected menu Pressing and holding either switch will speed up the scroll rate which can be helpful to speed up the configuration time The EXECUTE switch is normall...

Page 13: ...MX A B 2 ROOM or PATCH When DMX is not being received the top line of the LCD display shows MADD 24 unless the system is in standby mode then STANDBY is displayed The bottom line of the LCD Display shows the current status of the system unless the system configuration menu items are being accessed Below are descriptions for each status indication NO RX Displayed when DMX is not being received on e...

Page 14: ...dimmer outputs are disabled and the fans are turned on to full until the temperature cools down to 178 F 81 C or less Refer to menu item REM TEMP on page 26 to view the current remote temperature CTL TEMP Displayed when the microcontroller senses an internal over temperature condition of 185 F 85 C or more All dimmer outputs are disabled and the fans are turned on to full until the temperature coo...

Page 15: ...puts when DMX is being received 24 STANDBY Enable or disable the power savings standby mode 25 TEST INC Set the test increment units to percent or hexadecimal 26 OC MODE Configure the input trigger parameters for the open collector output 27 AUX IN Select which scene the auxiliary input will trigger enable 28 L BUTTON Set the mode of the local buttons to scene bump or disabled 29 S ALARM Select th...

Page 16: ...D indicates the control channel C and level L C 24L 00 Press MENU to select the control channel C to modify from 01 to 24 C 24L 00 Press EXECUTE to toggle from channel C to level L selection C 24L 00 Press ESCAPE to toggle from level L to channel C selection C24L FL Press MENU to select the output level L for the selected channel from 00 to FL CLEAR Press EXECUTE to clear the selected preset and s...

Page 17: ...This menu does not timeout automatically and will continue to monitor indefinitely Press EXECUTE to enter the menu and activate monitor mode D 01L000 Press MENU to select the dimmer D output to monitor from 01 to 96 D 24L512 Display shows dimmer 24 has full on control Press ESCAPE or RESET to exit the menu NOTE The control value will not reach 512 when voltage output limiting is activated or when ...

Page 18: ...saved NOTE DMX O P must be set to OFFSET mode for this menu to function 8 2 RM SET Set the two room assignment for each of the dimmer outputs This menu is used to assign each of the 24 dimmer outputs to room A or room B Dimmer outputs assigned to room A are controlled via the DMX A input Dimmer outputs assigned to room B are controlled via the DMX B input This creates separation within the dimmer ...

Page 19: ...enable ENABLED Press and hold MENU and MENU at the same time for 4 5 seconds OFFSET Press EXECUTE to toggle the DMX mode from OFFSET to PATCH PATCH Press EXECUTE to toggle the DMX mode from PATCH to OFFSET Press ESCAPE or RESET to exit the menu Any change in the configuration is automatically saved 12 DMXA PAT Patch the 24 dimmer PWM outputs to any DMX A input channel There are two ways to configu...

Page 20: ...ck DIM 024 Press MENU to edit the dimmer number DIM from 001 to 024 DIM 001 Press MENU and MENU at the same time to toggle back to 001 DMXA 001 Press EXECUTE to select the DMX A DMXA start address for the block DMXA 512 Press MENU to edit the DMX A DMXA start address from 001 to 512 DMXA 001 Press MENU and MENU at the same time to toggle back to 001 DIM 001 Press EXECUTE to select the number of di...

Page 21: ...CUTE to toggle the pointer to select the control channel to patch D24 C01 Press MENU to select the desired control channel from 01 to 24 D24 C01 Press EXECUTE to toggle the pointer to select another dimmer output Press ESCAPE to exit the menu and save the desired dimmer channel patch Press RESET to exit the menu without saving The menu will automatically timeout after 2 minutes of inactivity and s...

Page 22: ... level for the selected dimmer outputs Load shed SHED mode is used as a power management interface to building management systems BMS Contact closure devices such as a photocell or maintained switch contact may be used to trigger the analog input When a voltage of 5 5VDC to 12VDC is sensed on the analog input the selected dimmer outputs are disabled set to zero output level The selected dimmer out...

Page 23: ...nputs and functions in a highest takes precedence HTP mode of operation ENABLED Press EXECUTE to toggle analog blocking from ENABLED to DISABLED DISABLED Press EXECUTE to toggle analog blocking from DISABLED to ENABLED Any change in the configuration is automatically saved 24 STANDBY Enable or disable the power savings standby mode When standby mode is enabled the microcontroller goes to sleep wit...

Page 24: ...ith JS ICON Series dimmer racks Setting the local buttons to scene mode puts the system in scene mode With scene mode enabled the selected scene will always be activated when DMX is not being received The selected scene can be changed in the SCENESET menu Scene mode enables the use of the auxiliary AUX input A contact closure sensed on the over temperature O T fire alarm FIRE or security alarm SCT...

Page 25: ...chase effects the delay may be undesirable in which case the lamp warming feature can be turned off Note that when standby mode is enabled the microcontroller goes to sleep within 5 seconds of inactivity on the control inputs and there is delay of 150 milliseconds for the microcontroller to wake up and restart normal run mode To ensure virtually instant dimmer control response set STANDBY to DISAB...

Page 26: ...e menu and view the line voltage of each phase ØA 120 0 Shows the line voltage of Phase A ØB 120 0 Press MENU to view the line voltage of Phase B ØC 120 0 Press MENU to view the line voltage of Phase C Press ESCAPE or RESET to exit the menu 35 LINE F View the line frequency of phase A 60 0 Hz Shows the frequency 36 REM TEMP View the temperature of the remote temperature sensor A thermostat measure...

Page 27: ...desired hard key code Press RESET to exit the menu without saving The menu will automatically timeout after 2 minutes of inactivity and save NOTE Be sure to record and file the hard key code on page 31 for future reference 40 SERIAL View the microcontroller s unique six character silicone serial number XXXXXX Shows the unique six character serial number 41 VERSION View the microcontroller s softwa...

Page 28: ...ed if the wrong product type of EEPROM memory module detected PRODUCT Displayed if the wrong product type of EEPROM memory module detected CRC ERR Displayed if the CRC test fails and the EEPROM memory module is defective WARNING Do not reset or turn the power off while the firmware is being updated Doing so will cause unrecoverable loss of firmware data that is being loaded into the MADD 24 microc...

Page 29: ...RIFY Automatically verifies parameter backup data and CRC value DONE Parameter backup is done and saved in the EEPROM memory module NO MEM Displayed if an EEPROM memory module is not detected WRONG Displayed if the wrong type parameter of EEPROM memory module detected MEM TYPE Displayed if the wrong type parameter of EEPROM memory module detected WRONG Displayed if the wrong product type of EEPROM...

Page 30: ... is AAAAAAAAAAAABBBBBBBBBBBB ØPATCH5 Phase patch for JS ICON 1220 with Single Phase power Dimmer phase assignment is AAAAAABBBBBB 13 24 are unused ØPATCH6 Phase patch for JS ICON 1210 620 with Single Phase power Dimmer phase assignment is AAAAAAAAAAAABBBBBB 19 24 are unused ØPATCH7 Patches all PWM output channels to ØA Not used with JS ICON product ØPATCH8 Phase patch for DE90 3000 Series retrofit...

Page 31: ...Serial Number ________________ Hard Key Code ______________________ JSI Serial Number ____________________ Silicone Serial Number ________________ Hard Key Code ______________________ JSI Serial Number ____________________ Silicone Serial Number ________________ Hard Key Code ______________________ JSI Serial Number ____________________ Silicone Serial Number ________________ Hard Key Code _______...

Page 32: ...ms com 32 Troubleshooting Reference This manual is accurate at time of printing and subject to revisions and technical updates as required without prior notice Please visit www johnsonsystems com for applicable updates ...

Page 33: ...ms com 33 Troubleshooting Reference This manual is accurate at time of printing and subject to revisions and technical updates as required without prior notice Please visit www johnsonsystems com for applicable updates ...

Page 34: ... 2400 Watt dimmers JS ICON 2410 24 x 10 Amp 1200 Watt dimmers JS ICON 2413 24 x 13 Amp 1560 Watt dimmers JS ICON 1210 620 12 x 10 Amp 1200 Watt 6 x 20 Amp 2400 Watt dimmers JSI ICON Series Dimmer Relay Racks User Manual JS ICON Series Dimmers Rev 3 ...

Reviews: