www.johnsonsystems.com
10
00000000
Press ESCAPE to move the cursor to the left or to exit the menu.
00000090
Press MENU ( ) to adjust the selected digit (0 to 9).
00000093
Repeat the previous 3 steps until the security key is complete.
00000093
Press ESCAPE to exit the menu and save the security key.
The menu will automatically timeout after 2 minutes of inactivity and save.
11. SET KEY
Set the security key for a CS-DMX control station.
To set the security key, the security jumper on the CS-DMX control station must be
installed in the disabled position. Once the security key has been set, the security
jumper on the CS-DMX control station needs to be installed in the enabled position to
lock the security key in the control station.
Once the security key for the CS-DMX control station has been set, and the security
jumper is installed in the enabled position, the security key set in the CS-IPRO must
match the security key in the control station to make any changes.
Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED
window, within 12" (30 cm).
SET KEY
Press EXECUTE to set the CS-DMX security key.
SENDING
Displayed briefly while data is being sent from the CS-IPRO.
OKAY
Indicates data has been successfully transferred from the CS-IPRO.
COMM ERR
Indicates a communication error has been detected. Try again.
CS LOCK!
Indicates the security jumper on the CS-DMX is enabled and locked.
INVALID!
Indicates a data error has been detected.
12. GET KEY
Get the existing security key from a CS-DMX control station.
To get the security key from a CS-DMX control station, the security jumper on the
control station must be installed in the disabled position.
Getting the existing security key from a CS-DMX control station, automatically loads
the 8-digit security key into the CS-IPRO memory.
Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED
window, within 12" (30 cm).
GET KEY
Press EXECUTE to get the CS-DMX security key.
CHECKING
Displayed briefly while data is being read and transferred.
00000093
Indicates the 8 digit security key.
COMM ERR
Indicates a communication error has been detected. Try again.
CS LOCK!
Indicates the security jumper on the CS-DMX is enabled and locked.
13. MONITOR
Monitor the slider level on a CS-DMX control station.
Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED
window, within 12" (30 cm).
MONITOR
Press EXECUTE to enter the menu.
S:01<00%
Indicates the selected slider (S) number (01) and level (00%) in percent.
S:12<00%
Press MENU ( ) to select the slider to monitor from 01 to 12.
S:12<FL%
The monitored slider level ranges from 00% to FL% (full/100%).
S:12<??%
If the infrared communication link is lost, the slider level is unknown (??%).
Press ESCAPE to exit the menu.
14. CHECK CS
Check the firmware version running on a CS-DMX control station.
Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED
window, within 12" (30 cm).
CHECK CS
Press EXECUTE to enter the menu.
CHECKING
Displayed briefly while data is being read and transferred.
VER X.X
Indicates the firmware version running on the CS-DMX control station.
COMM ERR
Indicates a communication error has been detected. Try again.
SLIDER
FIRMWARE
SECURITY
SECURITY