11
MDR/EN (0909) 1.0
2.7 Viscosity and specific gravity limits
Impeller
diameter
Max. viscosity cP
Specific gravity kg/dm
3
-1V
10
1.2
1VD
30
1.8
2.8 Sound level
Highest measured sound level for the MDR-pump is 70 dB(A) for pump fitted to standard
electric motor.