background image

TFP1253

Page 8 of 8

NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association

1400 Pennbrook Parkway, Lansdale, PA 19446 | Tel1-215-362-0700

© 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

FILTER HOUSING WITH 

LOWER HOUSING REMOVED

FILTER 

CARTRIDGE

BLACK 

DISC

WATER 

SEPARATOR

FILTER 

HOUSING

INLET BALL 

VALVE

OUTLET BALL 

VALVE

BYPASS BALL 

VALVE

DEPRESSURIZATION 

BALL VALVE

POWER ON/OFF 

SWITCH

BYPASS 

MODE 

ALARM 

INDICATOR

FIGURE 4 

MODEL NG-1 1150, NG-1 1500, NG-1 2000, AND NG-1 3000 STAND-ALONE 

NITROGEN GENERATOR FILTER CARTRIDGE REPLACEMENT

Step 10.

 Close the depressurization 

ball valve. The Nitrogen Generator can 

now be placed back into service.

Step 11.

 Turn the power supply to the 

unit ON.

Step 12.

 Close the Bypass Ball Valve.

Step 13.

 Open the Inlet and Outlet Ball 

Valves.

Compressors

Maintenance of the Compressor

For compressor maintenance, please 

refer to the manufacturer’s recom-

mended maintenance plan in the 

owner’s manual for the compressor.

Limited 

Warranty

For warranty terms and conditions, visit 

www.tyco-fire.com.

Ordering 

Procedure

TYCO will supply a list of required part 

numbers to order through regular sales 

channels. Contact your local business 

manager or sales person and specify 

the following:

Sizing of Nitrogen Generator

•  Total cumulative size of all dry/pre-

action sprinkler systems

•  Size of the largest single dry/preac-

tion sprinkler system

•  Total number of dry/preaction sprin-

kler systems

•  Supervisory pressure of all dry/pre-

action sprinkler systems

•  Required voltage needed for dry/pre-

action sprinkler system

Filter Replacement Kit

Filter Replacement Kit . . . . . . . . . . . . . TNGFLTS

Optional Monitoring Equipment

Model THGA Handheld Gas Analyzer. . THGA01

Model TSGA SMART Gas Analyzer. . . . TSGA01

Model TILD In-Line Corrosion Detector

Refer to Technical Data Sheet TFP1261 for 

ordering instructions.

Summary of Contents for tyco NG-1 1150

Page 1: ...on on TYCO Dry Air Vent TAV D and to TFP1263 for more information on TYCO SMART Air Vent TSV D System Assembly The TYCO Nitrogen Generator unit includes the following components Steel enclosure cabinet with mem brane type nitrogen generator no nitrogen gas storage and manual bypass Power supply 120 VAC Single phase 60Hz 230 VAC Single phase 50Hz Single point nitrogen air discharge 1 2 in NPT Hour ...

Page 2: ...4605 1150 4353 2300 8706 NG 1 1500 24 3 688 11000 41640 1440 5451 2880 10902 NG 1 2000 24 688 18500 70030 2025 7666 4050 15331 NG 1 3000 35 992 22500 85172 2900 10978 5800 21955 Notes a Capacity based on NFPA 13 30 minute fill requirement of largest single system Model Number Cabinet Without Bypass Cabinet With Bypass Weight Lbs kg Width Inches mm Height Inches mm Depth Inches mm Width Inches mm H...

Page 3: ... N2 Purity at Discharge 98 or greater maximum of 2 0 oxygen N2 Pressure at Discharge Minimum of 15 psig 1 bar Max of feed air pressure minus 15 psig 1 bar N2 Water Dew Point Typically less than 70 F 57 C Note When connecting a TYCO Stand Alone Nitrogen Generator to an existing dry pipe preaction fire sprinkler system the existing fire sprinkler system s must be limited to a maximum leak rate of le...

Page 4: ... The nitrogen air discharge plumb ing from the nitrogen generator is to be connected directly to the sprinkler system valve trim using a minimum of 1 2 in to 1 in black steel galva nized steel or copper piping The size of the nitrogen air supply line is to be based on the length of pipe between the nitrogen generator and the fire sprinkler systems along with the total volume of the fire sprinkler ...

Page 5: ...GENERATOR RUNNING OUTPUT BYPASS MODE ALARM OUTPUT LEAK MONITORING OUTPUT POWER ON OFF OUTPUT NITROGEN SUPPLY LINE PRESSURE OUTPUT L1 N G PRESSURE SWITCH INCOMING POWER FUSE BOX BUILDING MANAGEMENT SYSTEM MONITORING POINTS POWER SUPPLY POWER DISTRIBUTION L1 G N N N G FIGURE 2A MODEL NG 1 1150 NG 1 1500 NG 1 2000 AND NG 1 3000 STAND ALONE NITROGEN GENERATOR AMERICAS SYSTEM SIGNAL MONITOR AND POWER S...

Page 6: ... drain connection be plumbed to a floor drain or building exterior When plumbing to a drain is not feasible an evaporative collection chamber can be used Note Ensure that the receiver tank auto drain is connected to an un switched power source 120 VAC for Americas 230 VAC for EMEA and APAC Note The Low Oil Level Sensor on the air compressor automatically shuts down air compressor until the proper ...

Page 7: ...rnal inlet piping by slowly opening the Depressurization Ball Valve in the cabinet to the left of the filter housing Step 4 Remove the filter housing by pulling down on the blue housing lock and turning the filter housing count er clock wise Step 5 Once the filter housing has been removed the filter cartridge inside is removed by first unscrewing the black retaining disc at the base of the cartrid...

Page 8: ...he Bypass Ball Valve Step 13 Open the Inlet and Outlet Ball Valves Compressors Maintenance of the Compressor For compressor maintenance please refer to the manufacturer s recom mended maintenance plan in the owner s manual for the compressor Limited Warranty For warranty terms and conditions visit www tyco fire com Ordering Procedure TYCO will supply a list of required part numbers to order throug...

Reviews: