Ordering Information 

T2000 Series Thermostat 

Model 

System 

Switch 

Fan Control 

Temperature 

Scale 

Power Supply 

Standard 

T2000AAC-0C0 

Heat-Off-Cool 

High-Med-Low 

10 - 30°C

 

110 & 230V 

None 

T2000EAC-0C0 

On-Off 

High-Med-Low 

10 - 30°C

 

110 & 230V 

None 

T2000HHC-0C0 

None 

None 

10 - 30°C

 

110 & 230V 

None 

T2000AAF-0C0 

Heat-Off-Cool 

High-Med-Low 

50 - 86°F

 

110 & 230V 

None 

T2000EAF-0C0 

On-Off 

High-Med-Low 

50 - 86°F

 

110 & 230V 

None 

T2000HHF-0C0 

None 

None 

50 - 86°F

 

110 & 230V 

None 

T2000AAT-0C0 

Heat-Off-Cool 

High-Med-Low 

10 - 30°C / 50 - 86°F

 

24V 

None 

T2000EAT-0C0 

On-Off 

High-Med-Low 

10 - 30°C / 50 - 86°F

 

24V 

None 

T2000HHT-0C0 

None 

None 

10 - 30°C / 50 - 86°F

 

24V 

None 

 

EQUIPMENT LISTS 

Valve and Actuator 

Valve Model 

Body 

Type 

Size 

End 

Connection 

Kv. 

Actuator 

Model 

Power Supply 

VB-5471-1060 

2-way 

15mm 

BSP Parallel 

1.6 

VA-7010-8503 

230V, 50/60Hz 

VB-5471-2080 

2-way 

20mm 

BSP Parallel 

3.5 

VA-7010-8503 

230V, 50/60Hz 

VB-5471-3090 

2-way 

25mm 

BSP Parallel 

5.5 

VA-7010-8503 

230V, 50/60Hz 

VB-5871-1060 

3-way 

15mm 

BSP Parallel 

1.6 

VA-7010-8503 

230V, 50/60Hz 

VB-5871-2080 

3-way 

20mm 

BSP Parallel 

3.5 

VA-7010-8503 

230V, 50/60Hz 

VB-5871-3090 

3-way 

25mm 

BSP Parallel 

5.5 

VA-7010-8503 

230V, 50/60Hz 

 

Specification for Valve and actuator, refer to VB-5000 Valve and VA-7010 Product Bulletin for 
details. 

 

ACCESSORIES 

Y620 Fan Control Switch 

Model 

Y621-0 

Y622-0 

System Switch 

On-Off 

Heat-Off-Cool 

Fan Switch 

High-Med-Low 

High-Med-Low 

Summary of Contents for T2000 series

Page 1: ...rmostats are used for low line voltage application and typical uses include fan coils electrical heaters and air handling units FEATURES q Rust proof plastic base and cover q System OFF position breaks all circuits q No leveling and vibration problems Figure 1 T2000AAC 0C0 Shown Figure 2 T2000HHC 0C0 Shown Features and Benefits q Close 0 5 to 0 8 C 1 to 1 1 2 F Typical Differential Provides steady...

Page 2: ...level is 1 5 meter above floor finishing level Avoid mount where thermostat can be affected by drafts radiant heat from the sun or other sources of heat HEAT OFF COOL HIGH MED LOW Y62x Installation T2000 xAx Installation T2000HHx Installation DIMENSIONS T2000xxx 0C0 88 00mm 133 00mm 2 5 3 0 15 1 0 20 HEAT OFF COOL HIGH MED LOW 42 50mm T2000HHx 0C0 Y62x 0 34 00mm 19 00mm 84 00mm 84 00mm 2 5 3 0 15 ...

Page 3: ...g Cooling 4 pipe System with 3 speed Fan Control T2000EAx 0C0 Cooling Only 2 pipe System with 3 speed Fan Control Heating Cooling Only 2 pipe System with 3 speed Fan Control and Automatic Changeover T2000HHx 0C0 Cooling Only 2 pipe System Cooling Only 2 pipe System with 3 speed Control Switch 2 pipe System with Automatic Changeover Heating Cooling 4 pipe System with 3 speed Control Switch ...

Page 4: ...10 30 C 50 86 F 24V None T2000HHT 0C0 None None 10 30 C 50 86 F 24V None EQUIPMENT LISTS Valve and Actuator Valve Model Body Type Size End Connection Kv Actuator Model Power Supply VB 5471 1060 2 way 15mm BSP Parallel 1 6 VA 7010 8503 230V 50 60Hz VB 5471 2080 2 way 20mm BSP Parallel 3 5 VA 7010 8503 230V 50 60Hz VB 5471 3090 2 way 25mm BSP Parallel 5 5 VA 7010 8503 230V 50 60Hz VB 5871 1060 3 way...

Page 5: ...22kg Standard None None None Y620 Fan Control Switch Product Code Y621 0 Y622 0 System Switch On Off Heat Off Cool Fan Switch High Med Low High Med Low Material Finish Moulded ABS Plastic with UL94 V0 in white colour Electrical Ratings 10 1 A 120V 50 60 Hz Wiring Connections Screw in terminals capable of accepting wires up to 1 5mm The performance specifications conform to acceptable industry stan...

Reviews: