Operating manual – DualPAC with reciprocating compressors
44/63
0012201 en 2021.04
Caution!
Wire connections to the motor and VSD must
not
be touched immediately after the DualPAC unit
is powered down as the capacitors in the VSD may still be charged. Read the warning label on the
VSD.
5.5.2
Shutting down for a long standstill period
Follow the
Stopping for a brief period
instructions and:
1.
Turn off the oil heater and heat tracing.
2.
Close suction and discharge valves.
3.
Rotate the motor and compressor (weekly/monthly according to below).
4.
If the compressor is water-cooled, drain of the water.
To reduce the risk of bearing damage, it is recommended to rotate (to a new position) the motor
and compressor on a monthly basis. If the DualPAC is exposed to vibrations during a long shut-
down period, the position should be changed weekly. Avoid high vibration level.