Enrollment
Compatible panels
•
PowerSeries NEO (v1.37 and higher)
•
PowerSeries Pro (v1.31 and higher)
•
IQ2+ (v2.6.2 and higher)
•
IQ Hub (v3.0.1 and higher)
•
IQ4 (v4.0.1 and higher)
Enrolling the device
The device begins the enrollment process when the PowerG module is powered on. The PowerG module is a card in
the detector.
Note
: Enroll both the transmitter and receiver onto the control panel. The modules can be enrolled in any order.
Figure 8. Internal view
A
PowerG daughter card
B
PowerG power switch
C
Configuration dipswitches
Configuration
Dipswitch 1
Dipswitch 2
Receiver
On
On
Transmitter
Off
On
1. Ensure the control panel is in enrollment mode.
2. Install batteries in the detector.
3. Turn the PowerG module power switch located on the interface board to the ON position. Refer to the control
panel installation manual for a complete set of enrollment instructions.
If the automatic enrollment procedure fails, refer to the control panel instructions and enroll the device
manually.
4.
Optional
: Configure any optional settings on the interface board. For more information, see the
Optional
settings
section.
5.
Important!
Turn the switch to the OFF position and remove the batteries. Reinsert the batteries after you
mount the device
.
Note:
Complete enrollment for both the transmitter and receiver before mounting the device.