[02] Instant Stay Arm
This feature is similar to the Stay Arm function key, except that no exit delay is applied and the
system arms immediately.
If no Stay/Away zone types are programmed, the alarm system arms in Away mode.
Note:
Do not use this function with CP-01 installations.
[03] Stay Arm
Only perimeter zones are armed. Interior zones are bypassed regardless of whether or not delay
zones are tripped during the exit delay.
[04] Away Arm
All interior and perimeter zones are armed. CP-01 panels require an exit through a delay zone
during the exit delay or the system will arm the perimeter zones only.
[05] No-Entry Arm [*][9]
All Delay 1 and Delay 2 zones become instant zones. If a door or window is opened the system goes
immediately into alarm. This function is typically used when no occupants are expected to return to
the site during the armed period. Activation of this function key requires an access code.
[06] Chime On/Off
This function turns the door chime on or off and is the equivalent of pressing [*][4]. The alarm
system must be disarmed to use this function. If option 7 in section [023] is enabled, this function
key requires an access code.
[07] System Test
This function performs a system test when pressed and is the equivalent of entering [*][6][Access
Code][04]. The alarm system must be disarmed to use this function.
for more
information.
[09] Night Arm
All perimeter and interior zones, excluding Night zones, are armed. This key only works while the
system is disarmed or armed in Stay mode.
If no Night type zones are programmed, the alarm system arms in Away mode with an audible exit
delay. Exit delay is silent.
Arming in this mode activates the Away Arming PGM output.
[12] Global Stay Arm
This function arms all partitions assigned to the user in Stay mode, provided they are ready to arm.
If a partition is not ready, the system cannot be armed. An access code is required with this option.
[13] Global Away Arm
This function arms all partitions assigned to the user in Away mode, provided they are ready to
arm. If a partition is not ready, the system cannot be armed. An access code is required with this
option.
[14] Global Disarming
This function disarms all partitions assigned to the user. An access code is required with this option.
53