[*][9] No-Entry Arming
This function is used to arm the alarm system while occupants are on the premises. Pressing [*][9]
and then keying in an access code arms the panel without an entry delay on delay type zones and
bypasses stay/away and night type zones.
After the exit delay, delay 1 and delay 2 type zones behave the same as instant zones. Stay/away
zones remain bypassed. The entry delay can be activated or deactivated at any time while the
system is armed using [*][9].
Note:
If the alarm system is armed using [*][9], disarming is only possible from a keypad
inside the premises unless a wireless key is used.
Note:
Entry of a valid access code is required following this key only when the system is
disarmed. When armed, if programming section [015] option 4 (Quick Arming/Function Key) is
off, an access code entry is required.
Global delay zones always have an entry delay, even if the system is armed using [*][9].
[*][0] Quick Arm/Exit
This feature operates differently depending on whether or not the alarm system is armed or
disarmed.
When disarmed:
Pressing [*][0] arms the alarm system without having to enter an access code. This provides a fast
method of arming for regular users and allows users without an access code to arm the system.
Note:
The Quick Arm feature (section [015] option 4) must be enabled in order for this
function to operate as intended. Function keys also will not require an access code when this
option is enabled.
When armed:
This feature provides a means to exit the premises while the alarm system is armed without having
to disarm then rearm it.
Pressing [*][0] starts a 2-minute timer that enables any door programmed as a delay zone to be
opened and closed once without triggering an alarm.
If the door is not closed at the end of the 2-minute timer, the entry delay sequence begins. Any
additional activity on another zone triggers the associated alarm or delay sequence.
SMS Command and Control
The user can perform certain functions on the alarm panel by remote using SMS text messages. In
addition, the system sends SMS messages to the user to confirm commands . SMS programming
options are accessed through programming section [851].
The security system only responds to SMS messages sent from designated phone numbers
(programmed in section [851]>[311]-[342]).
For more information on SMS command and control, and for a complete listing of communicator
programming options, refer to the alternate communicator installation manual.
SMS Command and Control Functions
The following alarm system functions are controllable via SMS:
• Stay arm the system
71
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference