8 - Telephone Line Monitor Audible When Armed
ON: When the system is disarmed, a telephone line monitor trouble generates a trouble indication
as described above. If the system is armed, a telephone line monitor trouble generates an audible
alarm on the siren for the duration programmed for bell timeout or until an access code is entered
to disarm.
OFF: Telephone line troubles generate a trouble indication, the Trouble LED illuminates, and the
keypad buzzer beeps until a key is pressed.
[016] System Option 4
1 - AC Trouble Display
ON: If AC power fails, the condition is reported to the monitoring station and is indicated as a
trouble condition on the system keypads.
OFF: If AC power fails, the condition is reported, but the Trouble light on the system keypads is off.
The trouble is displayed in [*][2].
Note:
Must be ON for UL/ULC listed installations.
2 - AC Trouble Light Flashes
ON: When AC power is lost, the Trouble light flashes in the base “Ready” and “Armed” mode within
30 seconds of power loss. When AC restores, the Trouble light stops flashing within 30 seconds. If
enabled, this option overrides the AC display option.
OFF: When AC power is lost, the Trouble light illuminates but does not flash.
5 - Keypad Blanking
ON: If no keys are pressed for 30 seconds, all keypad lights except backlighting (if enabled) are shut
off until the next keypress, entry delay, audible alarm or keypad buzzer condition.
Keypad function keys still operate when the keypad is blank, unless the function key is programmed
to require an access code. Keypad Blanking While Armed overrides this feature. When a partition
is armed and in alarm, entering a code to remove blanking silences the alarm and disarms the
system.
OFF: The keypad lights remain ON at all times.
4 - Keypad Blanking Requires Code
ON: A valid access code must be entered before a blanked keypad can be used. Information
becomes inaccessible to level 1 users.
OFF: Pressing any key on a blanked keypad removes keypad blanking.
Note:
Keypad Blanking Requires Code must be set to off for CP-01 listed installations.
5 - Keypad Backlighting
ON: All keypads on the system have backlighting on at all times.
OFF: All keypads on the system have backlighting off.
6 - Power Save Mode
ON: If AC power fails, all keypad lights including backlighting are shut OFF. The keypad lights come
back ON after a keypress, entry delay, audible alarm or keypad buzzer condition (except door
chime). Keypad lights return to the off state after 30 seconds of inactivity.
OFF: If AC power fails, keypads do not go into power save mode.
7 - Bypass Display When Armed
ON: The Bypass status light is on if zones are bypassed when the system is armed.
115
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference