SECTION X: INSTRUCTING THE OWNER
Assist owner with processing warranty cards and/or online registration.
Review Owners Guide and provide a copy to the owner and guidance
on proper operation and maintenance. Instruct the owner or the opera-
tor how to start, stop and adjust temperature setting.
When applicable, instruct the owner that the compressor is equipped
with a crankcase heater to prevent the migration of refrigerant to the
compressor during the “OFF” cycle. The heater is energized only when
the unit is not running. If the main switch is disconnected for long peri-
ods of shut down, do not attempt to start the unit until 8 hours after the
switch has been connected. This will allow sufficient time for all liquid
refrigerant to be driven out of the compressor.
The installer should also instruct the owner on proper operation and
maintenance of all other system components.
MAINTENANCE
1. Dirt should not be allowed to accumulate on the outdoor coils or
other parts in the air circuit. Clean as often as necessary to keep the
unit clean. Use a brush, vacuum cleaner attachment, or other suit-
able means.
2. The outdoor fan motor is permanently lubricated and does not
require periodic oiling.
3. If the coil needs to be cleaned, it should be washed with Calgon
Coilclean (mix one part Coilclean to seven parts water). Allow solu-
tion to remain on coil for 30 minutes before rinsing with clean water.
Solution should not be permitted to come in contact with painted
surfaces.
4. Refer to the furnace or air handler instructions for filter and blower
motor maintenance.
5. The indoor coil and drain pan should be inspected and cleaned reg-
ularly to prevent odors and assure proper drainage.
IT IS UNLAWFUL TO KNOWINGLY VENT, RELEASE OR DIS-
CHARGE REFRIGERANT INTO THE OPEN AIR DURING REPAIR,
SERVICE, MAINTENANCE OR THE FINAL DISPOSAL OF THIS
UNIT.
TABLE 2:
R-410A Saturation Properties
TEMP.
°
F
PRESSURE
PSIG
TEMP.
°
F
PRESSURE
PSIG
TEMP.
°
F
PRESSURE
PSIG
TEMP.
°
F
PRESSURE
PSIG
TEMP.
°
F
PRESSURE
PSIG
45
129.70
60
169.60
75
217.40
90
274.10
105
340.50
46
132.20
61
172.60
76
220.90
91
278.20
106
345.30
47
134.60
62
175.50
77
224.40
92
282.30
107
350.10
48
137.10
63
178.50
78
228.00
93
286.50
108
355.00
49
139.60
64
181.60
79
231.60
94
290.80
109
360.00
50
142.20
65
184.60
80
235.30
95
295.10
110
365.00
51
144.80
66
187.70
81
239.00
96
299.40
111
370.00
52
147.40
67
190.90
82
242.70
97
303.80
112
375.10
53
150.10
68
194.10
83
246.50
98
308.20
113
380.20
54
152.80
69
197.30
84
250.30
99
312.70
114
385.40
55
155.50
70
200.60
85
254.10
100
317.20
115
390.70
56
158.20
71
203.90
86
258.00
101
321.80
116
396.00
57
161.00
72
207.20
87
262.00
102
326.40
117
401.30
58
163.90
73
210.60
88
266.00
103
331.00
118
406.70
59
166.70
74
214.00
89
270.00
104
335.70
119
412.20