background image

5396714-BUM-C-0919

6

Johnson Controls Ducted Systems

 

ITEM

DESCRIPTION

EBE10A

EBE12A

EBE15A

<

1

Front Panel (Louvered, Insulated)

3501-9211

3501-9211

3501-9211

2* 

(Opt)

Front Panel (Solid, Insulated)

3501-9111

3501-9111

3501-9111

3

Filter (16 x 20 x 1)

S1-1214-2511

S1-1214-2511

S1-1214-2511

4

Support Angle.Top (Door)

S1-3500-1861

S1-3500-1861

S1-3500-1861

5

Cover, Electric Box

S1-3500-2351/A

S1-3500-2361/A

S1-3500-2361/A

6

Cover (Service Entrance)

S1-3500-1271

S1-3500-1271

S1-3500-1271

7

Sub-base

S1-3500-1071/B

S1-3500-1071/B

S1-3500-1071/B

8

---

---

---

---

9

Blower Housing

S1-37323744001

S1-37323744001

S1-37323744001

10

Blower Motor, Standard ECM (Prgm)

S1-02439707000

S1-02439707000

S1-02439707000

11

---

---

---

---

12

---

---

---

---

13

Motor Mount Assembly Kit (1PC)

S1-37319831002

S1-37319831002

S1-37319831002

14

Blower Wheel

S1-02632627700

S1-02632627700

S1-02632627700

15

Sequencer

S1-3110-3571

S1-3110-3571

S1-3115-3571

16

Transformer (240/24V-40A)

S1-3300-3861

S1-3300-3861

S1-3300-3861

17

Heater Element Assembly w/Limit and Jumper Wire

(9.6Kw)

S1-02541236000

(11.2Kw)

S1-02541238000

(4.8Kw) and (9.6Kw)

S1-02541237000
S1-02541236000

18

Limit Switch

S1-02541249000 (Open 

200, Close 140)

S1-02541249000 (Open 

200, Close 140)

S1-02541249000 (Open 

200, Close 140)

19

Fusible Link

S1-02541250000

S1-02541250000

S1-02541250000

20

Bracket (Circuit Breaker)

3500-128

3500-128

3500-128

21

Circuit Breaker (1 Required)

S1-3500-377P/A

---

---

Circuit Breaker (2 Required)

---

S1-3500-377P/A

S1-3500-377P/A

22

Buss Bar                           (See Note 2)

S1-3500-378P

S1-3500-378P

S1-3500-378P

23

Ground Lug (Large)

1216-231

1216-231

1216-231

Ground Lug (Small)

---

---

S1-02521798000

24

Drain Tube                        (See Note 1) 

S1-02922184001

S1-02922184001

S1-02922184001

25

Condensate Trap             (See Note 1) 

S1-3240-3051

S1-3240-3051

S1-3240-3051

26

Coil Shelf                           (See Note 1) 

3500-174

3500-174

3500-174

27

Coil Shelf Panel               (See Note 1) 

3500-171

3500-171

3500-171

28

Ferrule (3 Required)

S1-02320541000

S1-02320541000

S1-02320541000

29

Grommet (3 Required)

S1-02814740000

S1-02814740000

S1-02814740000

30

Fuse

S1-02532746026

S1-02532746026

S1-02532746026

31*

Wiring diagram

5395383

5395384

5395385

32*

Harness, Wire, ECM

S1-02550192000

S1-02550192000

S1-02550192000

33*

Cover, Service

S1-3500-1271

S1-3500-1271

S1-3500-1271

34

Relay, Control (1 Required)

S1-02436281000

S1-02436281000

---

Relay, Control (2 Required)

---

---

S1-02436281000

NOTE:

*Not Shown
New replacement parts shown in 

bold

 face type at the first printing of parts list dated 11/17.

Major components and suggested stocking items are shown with shaded item number.
“<“ Across from row indicates a change in that row.
--- Not applicable to specified model.
All parts with three digit suffix numbers are Special Order parts. These parts are subject to 
factory availability and require extra time for delivery.

1 Not factory installed. Contained in OEM purchased coils.
2 Standard on EBE12A.

Summary of Contents for EBE10A

Page 1: ...could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It is also used to alert against unsafe practic...

Page 2: ...f in the reverse order and the blower turns off LIMIT CONTROLS Each element has an automatic limit switch that is wired into the circuit The limit switch shuts off power to that element if the heat ex...

Page 3: ...f the furnace to gain access to the filter See Figure 1 For the upflow furnace the filter is located behind the return air grill adja cent to the furnace closet or any other location in the return air...

Page 4: ...ts downflow or upflow orientation to achieve higher airflow Refer to the installation instructions packed with the accessory package for more information FIGURE 3 EBE EUE Furnace Location of Component...

Page 5: ...5396714 BUM C 0919 Johnson Controls Ducted Systems 5 SECTION V REPAIR PARTS LIST FIGURE 4 EBE Downflow Application...

Page 6: ...reaker 3500 128 3500 128 3500 128 21 Circuit Breaker 1 Required S1 3500 377P A Circuit Breaker 2 Required S1 3500 377P A S1 3500 377P A 22 Buss Bar See Note 2 S1 3500 378P S1 3500 378P S1 3500 378P 23...

Page 7: ...S1 02541250000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 2 Required See Note 2 S1 3500 377P A S1 3500 377P A S1 3500 377P A 22 Buss Bar S1 3500 378P S1 3500 378P S1 350...

Page 8: ...5396714 BUM C 0919 8 Johnson Controls Ducted Systems FIGURE 5 EUE Upflow Application...

Page 9: ...500 128 3500 128 3500 128 21 Circuit Breaker 1 Required S1 3500 377P A Circuit Breaker 2 Required S1 3500 377P A S1 3500 377P A 22 Buss Bar See Note 2 S1 3500 378P S1 3500 378P S1 3500 378P 23 Ground...

Page 10: ...S1 02541250000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 2 Required S1 3500 377P A S1 3500 377P A S1 3500 377P A 22 Buss Bar S1 3500 378P S1 3500 378P S1 3500 378P 23 Gr...

Page 11: ...with Company promptly after installation This will initiate the warranty period and allow us to contact you should it become necessary You can register your product by returning the Warranty Registra...

Page 12: ...furnace 14 Damages caused by improper parts components or accessories not suitable for use in or with the unit For a list of parts that are known to be compatible reference equipment repair parts lis...