4
Installation and Maintenance
No.
Name
No.
Name
1
,QGRRUXQLW
8
Sealant
2
2XWGRRUXQLW
9
Wrapping tape
3
Connection pipe
10
6XSSRUWRIRXWGRRU
XQLW
4
Condensate
pipe
11
)L[LQJVFUHZ
5
:DOOPRXQWLQJ
frame
12
'UDLQDJHSOXJFRROLQJ
DQGKHDWLQJXQLW
6
Connecting
FDEOH
SRZHUFRUG
13
2ZQHU¶VPDQXDO
remote controller
7
Wall pipe
1. Safety Precaution
(1) All electric safety regulations must be followed when
installing the unit.
(2) Use proper power supply circuit and air switch in
accordance with local safety regulations.
(3) The power supply must be sized to meet the requirements
of air conditioning unit. Incorrect sizing/wiring may result in
electric shock,fire hazard or malfunction.
(4) Properly connect the live wire, neutral wire and grounding
wire of power socket.
(5) Be sure to cut off the main power supply before
performing any electrical work.
(6) Do not turn power back on until installation is complete.
(7) For appliances with type Y attachment,the instructions
shall contain the substance of thefollowing.If the supply cord
is damaged, it must be replaced by the manufacturer, its
service agent or a qualified technician to avoid any shock
hazards.
(8) The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper tube.
2.3 Installation - Checking Parts
2.4 Selection of Installation Location
2.5 Electric Connection Requirement
2.6 Installation of Indoor Unit
Air
C
onditioner
$LU
S
ZLWFK
C
DSDFLW\
30K
30A
36K
40A
Note:
3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ
'RQWXVH
an
XQTXDOL¿HGSRZHUFRUG
1. Basic Requirement:
,
nstalling the unit in the following places may cause
malfunction. If it is unavoidable, please consult the local dealer:
(1) Areas with strong heat sources, vapors, flammable or
explosive gas, or volatile objects spread in the air.
(2) Areas with high-frequency devices (such as welding
machine, medical equipment).
(3) Areas near coast.
(4) Areas with oil or fumes in the air.
(5) Areas with sulfureted gas.
(6) Other places with special circumstances.
2. Grounding Requirement
s
:
(1) The air conditioning unit must be properly grounded with a
specialized grounding device by a certified technician. Please
make sure it is always grounded effectively, otherwise it may
cause electric shock.
(2) The yellow-green wire in air conditioner is grounding wire,
which can't be used for other purposes.
(3) The grounding resistance should comply with national electric
safety regulations.
(4) The unit must be positioned so that the plug is accessible.
(5) An all-pole disconnect switch having a contact separation of
at least 1/8 inch in all poles should be connected in fixed wiring.
(6) Including an air switch with suitable capacity, please note the
following table. Air switch should be included magnet buckle and
heating buckle function, it can protect the circuitshort and
overload. (Caution: Please do not use only the fuse to
protect the circuit.)
1. Choosing Installation Location
Recommend installation location to the client based on field
conditions; then proceed after client approval.
2. Install Wall-mounting Frame
Install
WKHZDOOPRXQWLQJIUDPHRQWKHZDOODGMXVWLWLQ
KRUL]RQWDOSRVLWLRQZLWK
a
OHYHOPHWHUDQGWKHQ
plan
WKH
VFUHZ¿[LQJKROHVRQWKHZDOO
'ULOOWKHVFUHZ¿[LQJKROHVRQWKHZDOOZLWKLPSDFWGULOO
.
T
KH
VSHFLILFDWLRQRIGULOOKHDGVKRXOGEHWKHVDPHDVWKHSODVWLF
H[SDQVLRQSDUWLFOH
.
Then
¿OOWKHSODVWLFH[SDQVLRQSDUWLFOHV
in the
holes.
2. Indoor Unit:
(1) There should be no obstruction near air inlet and air outlet.
(2) Select a location where the condensation water can be
dispersed easily and won't affect other people.
(3) Select a location which is convenient to connect the
outdoor unit and near the power socket.
(4) Select a location which is out of reach for children.
(5) The location should be able to withstand the weight of
indoor unit and won't increase noise and vibration.
(6) The appliance must be installed 98 3/7 inch above floor.
(7) Don't install the indoor unit right above the electric
appliance.
(8) The appliance should not be installed in a laundry area.
3. Outdoor Unit:
6HOHFWDORFDWLRQZKHUHWKHQRLVHDQGRXWÀRZDLUHPLWWHGE\
WKHRXWGRRUXQLWZLOOQRWDIIHFWQHLJKERUKRRG
7KHORFDWLRQVKRXOGEHZHOOYHQWLODWHGDQGGU\LQZKLFKWKH
RXWGRRUXQLWZRQWEHH[SRVHGVWURQJ
wind
s
.
7KHORFDWLRQVKRXOGEHDEOHWRZLWKVWDQGWKHZHLJKWRI
RXWGRRUXQLW
0DNHVXUHWKDWWKHLQVWDOODWLRQIROORZVWKHUHTXLUHPHQW
s
RI
the
LQVWDOODWLRQGLPHQVLRQGLDJUDP
6HOHFWDORFDWLRQZKLFKLVRXWRIUHDFK
of
FKLOGUHQDQGIDU
DZD\IURPDQLPDOVRUSODQWV,ILWLVXQDYRLGDEOHSOHDVHDGG
a
IHQFHIRUVDIHW\SXUSRVH
s
(6) Install above the local snow line.
Summary of Contents for DCP30CSB21S