www.johnsonandstarley.co.uk
8.
FLAME LOSS
Should the flame signal be lost 5 times in any 4 minute period then the
boiler will lockout and an error code will be displayed in the centre of the
display. Pressing the reset will enable the boiler to relight.
If the fault recurs, turn off the boiler and consult a CORGI registered
installer.
9.
BOILER OVERHEATING
In the event of the boiler overheating the boiler will lockout and an error
code will be displayed in the centre of the display. Pressing the reset will
enable the boiler to relight.
If the fault recurs, turn off the boiler and consult a CORGI registered
installer.
10. WATER SYSTEM PRESSURE
The water system pressure is shown in the bottom right hand of the
display.
If the pressure drops below 1.0 bar it will begin to flash indicating the
system needs to be topped up by a competent person.
If the pressure continues to drop and reaches 0.6 bar, an error code
will appear in the centre of the display and all heat demands will be
blocked. This may indicate a leak and the system should be checked
before being re-pressurised.
11. CONDENSATE DRAIN
The condensate drain must not be modified or blocked.
Blockage of the condensate drain caused by debris or freezing, can
cause the boiler to lockout.
If freezing is suspected and the pipe run is accessible, then an attempt
to free the obstruction by pouring hot water on to the pipe may be
made. If this fails to remedy the problem, the assistance of a CORGI
registered installer should be sought.
12. SERVICE & MAINTENANCE
It is recommended that a full maintenance check be carried out
annually on the appliance. It is also recommended to take out a further
service agreement on the expiry of the guarantee period.
You can obtain further information on this from your gas supplier.
The appliance should be checked /serviced by a CORGI registered
installer.
If you require service on your appliance please contact your local
installer or gas supplier.
On completion of the service the installer should fill in the service
section at the rear of the BENCHMARK log book. All installers
registered with CORGI carry an identification card. This card will have
an ID number which should be recorded in your logbook.
If you have any queries regarding your installer you can contact CORGI
by telephone on 01256 372400.
13. ESCAPE OF GAS
Should a gas leak be suspected contact your gas supplier with out
delay.
Do not search for leak with a naked flame.
14. CLEANING THE APPLIANCE
The appliance casing should only be cleaned with a damp cloth then
dried.
Do not use abrasive or solvent cleaners.
ER:26
ER:03
1.0
bar
0.9
bar
ER:37