www.johnsonandstarley.co.uk
1. GENERAL DESCRIPTION
1.1
The Slim Line Cooker Hood is part of a whole house mechanical
ventilation system with heat recovery. You should read these
instructions in conjunction with the instructions provided with the
LE155/250 & LE155-1/250-1 heat recovery units.
1.2 HOW IT WORKS
Warm, humid, stale air from the kitchen is drawn through the cooker
hood by the exhaust fan of the heat recovery unit, before being
discharged to the outside.
IMPORTANT
1.3
Care must be taken to avoid the dangers of flue gases from fuel
burning appliances being drawn into the living area.
1.4
If the cooker hood is fitted in a room containing a fuel burning
appliance, such as a central heating boiler, then:
a. the flue of the fuel burning appliance must be either of the room
sealed, or balanced flue type, or
b. allowances must be made for an adequate supply of air
into the room.
1.5
The exhaust from the cooker hood must be connected to the
heat recovery system and not discharged into any other flue that is
being used for the exhaust of any fumes from fuel burning appliances.
1.6
The requirement of all Building Regulation and local authorities
concerned with the discharge of exhaust air must be observed.
2. INSTALLATION
2.1 This kit must be installed by a competent person. All
electrical wiring must be installed by a suitably qualified
person and conform with I.E.E. Regulations (current edition.).
2.2
The installation height is subject to local regulations, but MUST NOT BE
LESS THAN 600mm from the top of an electric cooker, or 700mm from
the top of a gas cooker.
2.3
A fused spur box, or double pole switch having a minimum contact
separation of 3mm, must be fitted for isolation of the unit.
2.4 INSTALLATION WITH A REMOTELY FITTED LE155/250 &
LE155-1/250-1 HEAT RECOVERY UNIT
2.4.1 Remove the grille from the cooker hood allowing access to the
screw positions on the inside of the unit.
2.4.1 Determine the location and height of the cooker hood and
mark off the 4 fixing hole positions using the hood as a
template.
2.4.2 Drill the 4 x 7.5mm holes and secure
the canopy in the required position
with the screws provided.
2.4.3 For surfaces other than masonry: a
purpose made fixing is to be used.
2.5
Connect the extract duct over the fire
damper and spigot and secure into
position.
2.6
Connect the pre-wired electrical cable
to the fused spur or double pole switch,
which is to be fused at 3A.
2.7
Reconnect the grille to the cooker hood
and close.
2.8
Over stick the label supplied onto the
circuit diagram label on the sealing
compartment door.
WARNING
Do not flambé whilst
using this appliance!
IMPORTANT
INFORMATION
WARNING - THIS APPLIANCE
MUST BE EARTHED!
BEFORE STARTING THIS
PROCEDURE, YOU MUST
ENSURE THE POWER SUPPLY
TO THE UNIT HAS BEEN
SWITCHED OFF!
FIGURE 1
Electrical Connection
AW2163 ISSUE 2 CHW-1