23
Burner and nozzle
characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31
28/37 mbar
Nozzle
diameter
1/100 mm
By-pass mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.0
50
30
350
73
71
Semi rapid
1.75
65
33
450
127
125
Triple crown
3.2
94
65
1500
233
229
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20
20 mbar
Nozzle diameter 1/100 mm
Reduced Flowrate (W)
Auxiliary
1.0
72
350
Semi rapid
1.75
97
450
Triple crown
3.2
133
1500