background image

Installing the Seal

(continued)

It is recommended that the seal cavity be vented through the pump’s lantern
ring connection located at top dead center. It is always recommended that a
flush injection be utilized. The flush should be piped into the seal gland to
ensure maximum efficiency.

For DIN pumps rotate gland 135˚ CCW. Use port #2 as flush.

NOTE: 

For CCW (counter clockwise) rotation pumps, 
consult John Crane engineering.

Clockwise

Rotation

Drain “D”

Type 5610V

Port #1   -   Not Drilled
Port #2   -   Flush
Port #3   -   Not Drilled
Port #4   -   Not Drilled

Flush “F”

Quench “Q”

Clockwise

Rotation

Port #1   -   Quench
Port #2   -   Flush
Port #3   -   Drain
Port #4   -   Not Drilled

Type 5610VQ

Flush “F”

Decommissioning the Equipment

  

1.

 Ensure that the equipment is electrically isolated.

      

If the equipment has been used on toxic or hazardous
fluids, ensure that the equipment is correctly decontami-
nated and made safe prior to commencing work.
Remember, fluid is often trapped during draining and
may exist outside the seal. The equipment instruction
manual should be consulted to check for any special pre-
cautions.

  

2.

 Ensure that the equipment is isolated by the appropriate valves.

Check that the fluid is drained and pressure is fully released.

Maintenance

No maintenance of a seal is possible while installed. Therefore, it is
recommended that a spare seal unit be held in stock to allow immediate
replacement of a removed seal.  

It is recommended that used seals are returned to a John Crane service
location, as rebuilding to as-new specifications must be carried out by
qualified personnel.

It is the responsibility of the equipment user to ensure that any
parts being sent to a third party have appropriate safe
handling instructions externally attached to the package.

Quality Assurance

This seal has been assembled in accordance with John Crane quality
assurance standards and with proper maintenance and use will give safe
and reliable operation to the maximum recommended performance as
shown in any relevant approved John Crane publication.

!

!

TYPE 5610V/5610VQ

SINGLE O-RING CARTRIDGE SEAL

Installation, Operation & Maintenance Instructions

PAGE

5

Summary of Contents for 5610V

Page 1: ...3 The seal is designed exclusively for sealing rotating shafts The manufacturer cannot be held liable for use of the seal for purposes other than this 4 The seal must only be used in technically perfect condition and must be operated within the recommended performance limits in accordance with its designated use set out in these installation instructions Dry running often indicated by a squealing ...

Page 2: ...l SAE 10 or 20 or silicone grease such as Dow Corning compound 4 For ethylene propylene elastomers do not lubricate with petroleum products 1 Place gland plate on table with gasket side facing up 2 Install lubricated O ring into outside diameter OD groove of mating ring 3 Stand sleeve on its base and slide mating ring over sleeve align pins and press in place 4 Install set screws in collar 5 Loose...

Page 3: ...25 3 338 1 500 2 187 2 250 2 680 4 875 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 525 3 599 1 625 2 312 2 375 2 812 5 000 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 562 3 766 1 750 2 406 2 480 2 918 5 250 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 563 3 875 1 875 2 549 2 625 2 918 5 250 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 563 3 875 2 000 2 673 2 750 3 015 5 500 2 963 1 601 2 312 1 032 2...

Page 4: ...lywater is a registered trademark of American Polyware Co GLAND BOLTS SPACERS CAP SCREWS Type 5610VQ Oversize Bore Single Cartridge Dimensional Data inches Seal D4 Min Size D1 D3 Min Max D26 L12 L23 L39 L56 L90 L91 L92 M N Turn Diam 1 375 1 939 2 875 3 023 5 375 2 062 1 446 2 062 0 625 2 125 0 791 0 666 0 562 4 062 3 268 1 750 2 406 3 500 3 925 6 500 2 156 1 487 2 125 0 656 2 187 0 744 0 619 0 687...

Page 5: ...t outside the seal The equipment instruction manual should be consulted to check for any special pre cautions 2 Ensure that the equipment is isolated by the appropriate valves Check that the fluid is drained and pressure is fully released Maintenance No maintenance of a seal is possible while installed Therefore it is recommended that a spare seal unit be held in stock to allow immediate replaceme...

Page 6: ... 625 H SP 1030367 H SP 1030399 1 750 H SP 1030368 H SP 1030400 1 875 H SP 1030369 H SP 1030401 2 000 H SP 1030370 H SP 1030402 2 125 H SP 1030371 H SP 1030403 2 250 H SP 1030371 H SP 1030404 2 375 H SP 1030373 H SP 1030405 2 500 H SP 1030374 H SP 1030406 2 625 H SP 1030375 H SP 1030407 2 750 H SP 1030376 H SP 1030408 2 875 H SP 1030377 H SP 1030409 3 000 H SP 1030378 H SP 1030410 3 125 H SP 103037...

Page 7: ...TYPE 5610V 5610VQ SINGLE O RING CARTRIDGE SEAL Installation Operation Maintenance Instructions PAGE 7 ...

Page 8: ...ns without prior notice It is dangerous to smoke while handling products made from PTFE Old and new PTFE products must not be incinerated ISO 9001 and ISO14001 Certified details available on request 2015 John Crane Revised 10 15 www johncrane com IOM 5610 5610VQ NorthAmerica United States of America Tel 1 847 967 2400 Fax 1 847 967 3915 Europe United Kingdom Tel 44 1753 224000 Fax 44 1753 224224 L...

Reviews: