WARNING

:  USE OF THIS PRODUCT FOR ANY PURPOSES OTHER THAN ITS ORIGINAL INTENT, ABUSE OF THE PRODUCT, AND/OR MODIFICATION TO THE ORIGINAL 

PRODUCT IS STRICTLY PROHIBITED BY JOHN BLUE COMPANY.  JOHN BLUE COMPANY RESERVES THE RIGHT TO DENY WARRANTY OR LIABILITY CLAIMS IN ANY/ALL 
SITUATIONS INVOLVING MISUSE, ABUSE OR MODIFICATION. 

  THE ORIGINAL INTENT OF THIS PRODUCT DOES NOT INCLUDE USE WHERE THE MAXIMUM ALLOWED PRESSURE OR TEMPERATURE IS EXCEEDED, AND IT 

DOES NOT INCLUDE APPLICATIONS UTILIZING FLUIDS THAT ARE NOT COMPATIBLE WITH THE PRODUCT’S COMPONENT MATERIALS.  DO NOT USE THIS PRODUCT WITH 
FLAMMABLE OR COMBUSTIBLE FLUIDS SUCH AS GASOLINE, KEROSENE, DIESEL, ETC...  FAILURE TO FOLLOW THIS NOTICE MAY RESULT IN SERIOUS INJURY AND/OR 
PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY.  IF IN DOUBT ABOUT YOUR APPLICATION, CONTACT YOUR STOCKING DEALER OR THE JOHN BLUE 
TECHNICAL STAFF AT 1-800-253-2583. 
 

WARNING:  

This product can expose you to certain chemicals, which are known to the State of California to cause cancer or birth defects or other reproductive harm.  For more information 

go to:  

www.P65Warnings.ca.gov

 

SAFETY PRECAUTIONS

:    EQUIPMENT SHOULD BE OPERATED BY RESPONSIBLE PEOPLE.  A CAREFUL OPERATOR IS THE BEST INSURANCE AGAINST AN ACCIDENT. 

 

 

   FILL SYSTEM WITH WATER FIRST AND CHECK FOR LEAKS – REPLACE HOSES WHEN WORN OR CRACKED. 

 

The CS-150 Centrifugal spray pump is available in four configurations, details of each configuration are 
outlined on the proceeding pages, the four configurations are:

 

 

1.) 

Shaft Drive (P/N: CS-150) 

2.) 

Hydraulic Drive (P/N: CS-150-HY)  

3.) 

Hydraulic Drive with Manifold (P/N: CS-150-HYM) 

4.) 

Gas Engine Drive (P/N: CS-150RG) 

 

Pump Specifications and Performance: 

 

  Max flow:     

 

125 gpm @ 3800 RPM 

  Max pressure:  

 

90 psi @ 4200 RPM 

  Shaft Size   

 

3/4” Inner Diameter 

  Pump Inlet Port Size: 

1-1/2” FPT & 220 Flange Inlet 

  Pump Outlet Port Size: 

1-1/4” FPT & 200 Flange Outlet 

Installation and 

Operation Manual

 

CS

150

 

Series

 

 

Cast Iron Wet-Seal 1-1/2” x 1-1/4” 

Centrifugal Spray Pump 

Summary of Contents for CS-150 Series

Page 1: ...HNICAL STAFF AT 1 800 253 2583 WARNING This product can expose you to certain chemicals which are known to the State of California to cause cancer or birth defects or other reproductive harm For more information go to www P65Warnings ca gov SAFETY PRECAUTIONS EQUIPMENT SHOULD BE OPERATED BY RESPONSIBLE PEOPLE A CAREFUL OPERATOR IS THE BEST INSURANCE AGAINST AN ACCIDENT FILL SYSTEM WITH WATER FIRST...

Page 2: ...f the pump this will void the warranty Storage After use flush the pump with a solution that will neutralize the fluid you have been pumping and then drain then fill the pump with RV antifreeze for storage Maintenance Inspect the seal reservoir fluid level using the sight window the fluid level should be above the middle of the window If the fluid is dirty drain the pump by vacuum or turning upsid...

Page 3: ...3023 8 6 1 8 NPT PLUG PLATED C 431 B 3 7 HOUSING 116380 01 1 8 BEARING HOUSING 116282 01 1 9 PEDESTAL 116381 01 1 10 BEARING 116385 01 2 11 DOUBLE SEAL CERAMIC 116386 01 1 12 HOUSING RETAINING RING 116387 01 1 13 SHAFT RETAINING RING 116388 01 2 14 HOUSING O RING VITON 166 116389 01 1 15 1 8 NPT PLUG PLATED A 29 4 16 3 8 24NF FLEXLOC NUT SS S 3557 1 17 SIGHT WINDOW 116384 01 1 18 ADAPTER O RING BU...

Page 4: ...e window If the fluid is dirty drain the pump by vacuum or turning upside down then replace with 50 50 premixed ethylene glycol antifreeze If fluid is cloudy impeller side seal may be leaking Hydraulic Drive Specifications Max Hydraulic Flow 4 GPM Max Hydraulic Pressure 3000 PSI Pump Port P Size SAE 6 Tank Port T Size SAE 8 Gauge Load Sense Port M1G LS SAE 4 Hydraulic line sizes should be sized ap...

Page 5: ... BEARING HOUSING 116282 01 1 9 PEDESTAL 116381 01 1 10 BEARING 116385 01 2 11 DOUBLE SEAL CERAMIC 116386 01 1 12 HOUSING RETAINING RING 116387 01 1 13 SHAFT RETAINING RING 116388 01 2 14 HOUSING O RING VITON 166 116389 01 1 15 1 8 NPT PLUG PLATED A 29 4 16 3 8 24NF FLEXLOC NUT SS S 3557 1 17 SIGHT WINDOW 116384 01 1 18 ADAPTER O RING BUNA 152 116390 01 1 19 HYDRAULIC MOTOR 116486 01 1 20 3 8 WASHE...

Page 6: ...y impeller side seal may be leaking Hydraulic Drive Specifications Max Hydraulic Flow 25 GPM Ideal Hydraulic Flow 4 GPM Max Hydraulic Pressure 3000 PSI Pump Port P Size SAE 10 Tank Port T Size SAE 10 Gauge Load Sense Port M1G LS SAE 4 Hydraulic line sizes should be sized appropriately to the flow capacity of the tractor supply and rated for 3000 PSI continuous operating pressure for flowrates from...

Page 7: ... 1 below to approximate sprayer flow desired Do not exceed 25 GPM hydraulic flow 4 Open sprayer system valve to desired sprayer pressure and flow If Tractor s Hydraulic System is Pressure Compensated 1 Shutoff sprayer system valve 2 Set Hydraulic flow from tractor supply to 0 4 GPM per Chart HYM 1 1 below to approximate sprayer flow desired Do not exceed 25 GPM hydraulic flow 3 Open sprayer system...

Page 8: ... 116386 01 1 11 HOUSING RETAINING RING 116387 01 1 12 SHAFT RETAINING RING 116388 01 2 13 HOUSING O RING VITON 166 116389 01 1 14 1 8 NPT PLUG PLATED A 29 4 15 3 8 24NF FLEXLOC NUT SS S 3557 1 16 SIGHT WINDOW 116384 01 1 17 ADAPTER O RING BUNA 152 116390 01 1 18 HYDRAULIC MOTOR W MANIFOLD 116494 01 1 19 3 8 WASHER 93024 2 20 3 8 16 1 1 4 HEX BOLT PLATED 90653 2 21 3 8 16 HEX NUT PLATED 92024 2 22 ...

Page 9: ...this will void the warranty Storage After use flush the pump with a solution that will neutralize the fluid you have been pumping and then drain then fill the pump with RV antifreeze for storage Maintenance Inspect the seal reservoir fluid level using the sight window the fluid level should be above the middle of the window If the fluid is dirty drain the pump by vacuum or turning upside down then...

Page 10: ... 2021 John Blue Co 10 CS 150RG Pump Components ...

Page 11: ...al reservoir fluid changes level Leak at the input shaft seal if level is low Leak at the impeller side seal if level is high ISSUE PROBABLE CAUSE Reduced sprayer pump water flow or water pressure Insufficient hydraulic flow or pressure from tractor Damaged O rings on valves in hydraulic motor manifold see Parts Breakdown section above Insufficient water pressure No water available Water pump exce...

Page 12: ...l lease or lend the equipment to be free from defects in material and workmanship under normal use and service This obligation of John Blue Company under this warranty is limited to the repair or replacement of defective parts or correction of improper workmanship of any parts of such equipment which shall within one year from the date of John Blue s original delivery thereof be returned to John B...