12-M-71 1
Rev.
11/2021
WARNING
: USE OF THIS PRODUCT FOR ANY PURPOSES OTHER THAN ITS ORIGINAL INTENT, ABUSE OF THE PRODUCT, AND/OR MODIFICATION TO THE ORIGINAL
PRODUCT IS STRICTLY PROHIBITED BY JOHN BLUE COMPANY. JOHN BLUE COMPANY RESERVES THE RIGHT TO DENY WARRANTY OR LIABILITY CLAIMS IN ANY/ALL
SITUATIONS INVOLVING MISUSE, ABUSE OR MODIFICATION.
THE ORIGINAL INTENT OF THIS PRODUCT DOES NOT INCLUDE USE WHERE THE MAXIMUM ALLOWED PRESSURE OR TEMPERATURE IS EXCEEDED, AND IT
DOES NOT INCLUDE APPLICATIONS UTILIZING FLUIDS THAT ARE NOT COMPATIBLE WITH THE PRODUCT’S COMPONENT MATERIALS. DO NOT USE THIS PRODUCT WITH
FLAMMABLE OR COMBUSTIBLE FLUIDS SUCH AS GASOLINE, KEROSENE, DIESEL, ETC... FAILURE TO FOLLOW THIS NOTICE MAY RESULT IN SERIOUS INJURY AND/OR
PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY. IF IN DOUBT ABOUT YOUR APPLICATION, CONTACT YOUR STOCKING DEALER OR THE JOHN BLUE
TECHNICAL STAFF AT 1-800-253-2583.
WARNING:
This product can expose you to certain chemicals, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information
go to:
www.P65Warnings.ca.gov
.
SAFETY PRECAUTIONS
: EQUIPMENT SHOULD BE OPERATED BY RESPONSIBLE PEOPLE. A CAREFUL OPERATOR IS THE BEST INSURANCE AGAINST AN ACCIDENT.
FILL SYSTEM WITH WATER FIRST AND CHECK FOR LEAKS – REPLACE HOSES WHEN WORN OR CRACKED.
The CS-150 Centrifugal spray pump is available in four configurations, details of each configuration are
outlined on the proceeding pages, the four configurations are:
1.)
Shaft Drive (P/N: CS-150)
2.)
Hydraulic Drive (P/N: CS-150-HY)
3.)
Hydraulic Drive with Manifold (P/N: CS-150-HYM)
4.)
Gas Engine Drive (P/N: CS-150RG)
Pump Specifications and Performance:
Max flow:
125 gpm @ 3800 RPM
Max pressure:
90 psi @ 4200 RPM
Shaft Size
3/4” Inner Diameter
Pump Inlet Port Size:
1-1/2” FPT & 220 Flange Inlet
Pump Outlet Port Size:
1-1/4” FPT & 200 Flange Outlet
Installation and
Operation Manual
CS
‐
150
Series
Cast Iron Wet-Seal 1-1/2” x 1-1/4”
Centrifugal Spray Pump