background image

4

Joerns® Bed Frames
EasyCare

®

 

© 2015 Joerns Healthcare • 6110158 RevC • 15-2537

Bed System Entrapment Information

Although essential in the practice of long-term care, 

bedside rails, in recent years, have also been a 

subject of regulatory review and evolution in design 

and use.

That focus includes not only the challenge of achieving 

an appropriate balance between resident security and 

unnecessary restraint, but also the additional safety 

issue of entrapment.

The U.S. Food and Drug Administration (FDA), 

working with our company and other industry 

representatives has addressed the potential danger 

of entrapment with new safety guidelines for medical 

beds. These guidelines recommend dimensional  

limits for critical gaps and spaces between bed  

system components.

Entrapment zones involve the relationship of 

components often directly assembled by the 

healthcare facility rather than the manufacturer. 

Therefore, compliance is the responsibility of 

 

the facility.

As the leading manufacturer of long-term care beds 

and a frontrunner in addressing this critical issue, 

Joerns Healthcare can offer you the expertise, 

assistance and products to bring your facility 

 

into compliance.

Joerns

®

 Compliance Solutions

Matching the right bed components in order to meet 

regulatory guidelines can be complex.

That is why Joerns offers a wide array of compliance 

options. We assist customers in selecting compliant 

accessories recommended for their specific 

 

bed model.

Creating a Safer Care Environment

While the guidelines apply to all healthcare settings, 

(hospitals, nursing homes and at home), long-term 

care facilities have particular exposure since serious 

entrapment events typically involve frail, elderly or 

dementia patients.

Table of Contents

Important Precautions ...................................................................................................................................................2

Entrapment Information .................................................................................................................................................4

Features & Specifications

 ..............................................................................................................................................5

Assembly

 .......................................................................................................................................................................6

Operation 

 ......................................................................................................................................................................

8

Bed Transport...............................................................................................................................................................10

Care-Fit Integrated Width (option)................................................................................................................................11

Servicing ......................................................................................................................................................................12

Troubleshooting ...........................................................................................................................................................14

Maintenance ................................................................................................................................................................14

Preventative Maintenance ...........................................................................................................................................14

Cleaning ......................................................................................................................................................................14

Accessories .................................................................................................................................................................15

Warranty

 ......................................................................................................................................................................

18

Summary of Contents for EasyCare

Page 1: ...User Service Manual Joerns Bed Frames EasyCare Bed To avoid injury read user s manual before using...

Page 2: ...rom any outlet Warning Possible Shock Hazard Injury may result from improper routing of the power cord Always follow the proper factory installed routing configuration Failure to do so could result in...

Page 3: ...if mattress used with Mattress Side Stop does not fill the entire width between stops or which compresses to less than 1 5 inches under user s weight Warning Possible Injury or Death Floor locks incr...

Page 4: ...Therefore compliance is the responsibility of the facility As the leading manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the ex...

Page 5: ...tection LA27 Actuators Auto Reset Current Sensor Environmental Conditions Operating Conditions Ambient Temperature 10 C to 40 C Relative Humidity 30 to 75 Non Condensing Atmospheric Pressure 700 hPa t...

Page 6: ...ain support of the bed panel Insert the safety pins on each side and latch them Figure 3 6 Press the mounting bracket against the bed frame and tighten the four panel mounting screws right and left si...

Page 7: ...h 12 printed on it It is longer than the standard bumper 1 Remove the shorter bumper by tapping the tangs on either side of the leg with a rubber mallet 2 Place the 12 baseboard bumper 3 Tap into plac...

Page 8: ...3 Ensure that the cable plug is fully inserted into the cable jack 4 To secure tighten the union nut on both cables Figure 14 Operation Pendant Operation Your EasyCare bed comes standard with one of t...

Page 9: ...tion button Standard Staff Control Figure 21 2 1 4 6 5 3 7 Advanced Staff Control Figure 22 8 2 12 7 1 4 6 5 3 9 10 11 Head Operation 1 Push to raise Back 2 Push to lower Back Knee Operation 3 Push to...

Page 10: ...Install correct baseboard bumper Bed Transport Roll in Low Lock System 1 To keep the bed from rolling when in the lowest position press down on the locking lever to lock casters Figure 23 2 The stand...

Page 11: ...re 28 and 29 5 Release the tether to engage the detent Figure 27 6 Repeat the above steps on the remaining MSP extensions Warning Possible Injury Or Death Use a mattress that is properly sized to fit...

Page 12: ...in intact and are securely fastened to their intended connection point Actuator and Control Box Information Warning Possible Shock Hazard Unplug the power cord from the wall outlet before performing a...

Page 13: ...iver Masking Tape Zip Ties 5 16 Nut Driver 1 Raise the bed so that there is about 27 inches of clearance between the floor and the mattress support platform of bed 2 Unplug the power cable from the ou...

Page 14: ...k of use check all threaded fasteners for looseness and make sure all pins are in their normal location and fastened securely Check monthly for loose bolts nuts pins and other retaining hardware Tight...

Page 15: ...the floor and or cause the bed to become unstable resulting in injury or death Drainage Bag Holder Warning Possible BioHazard Prior to use consult the Drain Bag manufacturer s installation and use in...

Page 16: ...igure 36 1 The Drainage Bag Holder is designed as an attachment point for items such as urine collection bags Make sure items attached to holder are safely secured Prior to use please read important w...

Page 17: ...be fully charged Note We recommend that users charge up the Battery immediately upon receipt 4 The Battery has a useful life of about 3 5 years depending upon usage It is recommended to discharge the...

Page 18: ...are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to supplying replacement parts servicing or replacing at its option any product which is fo...