- User Manual v 3.1
Menu to 9-pin. Feed the LTC timecode and 9-pin from the master edit
controller.
When the BlackBox receives the RECORD command over 9-pin it will enter
record and timestamp the files with the incoming timecode. After recording,
the audio can be replayed and reviewed synchronously against any video
recording by issuing a PLAY command and feeding the same LTC timecode.
Chase setup Menu.
Here you have the option to offset the incoming
timecode by a specified amount of time in hours, minutes, seconds, frames
or bits.
Failover Operation
Failover Mode
can be set to Off, Main, or Backup. Failover mode can only be
used with two balanced BlackBox units. The units are wired together so that
the outputs of the main unit are fed into the inputs on the backup unit and
the outputs of the backup unit are in turn fed into the console or audio
amplifiers. When a system is set to Main, the BlackBox Player will output a
continuous tone from the channel selected under
Failover Channel.
When
set to Backup, the unit monitors this channel for the tone generated by the
Main system and automatically switches the relays to the Backup unit’s
audio if the tone from the Main unit fails (power failure/USB failure etc). The
output tone from the Main unit (tone out) and the monitoring of the tone
monitored by the Backup unit (tone in) must be set to the same channel for
this to work. The
Backup Armed (Standby)
and
Backup Take Over
options
become active on the Backup system and the title bar on the Backup system
will show that it is standing by to take over should a problem occur.
A common way of triggering a pair of players is by using a footswitch. As an
optional chargeable accessory, JoeCo supplies a footswitch splitter box that
allows users to control two BlackBox Players or Recorders using only one
footswitch. It is important that both BlackBox units have the same