background image

GENERAL WARRANTY TERMS 

1. 

The warranty is valid only on presentation of invoice of purchase.  

2. 

This  WARRANTY  is  limited  exclusively  to  parts  substitution  ineffective  due  to  faulty 
manufacture, made in our workshops.  

3. 

The  elimination  of  several  faults  of  the  scope  of  the  guarantee  is  made  for  repair  or 
replacement  of  defective  parts,  according  to  the  discretion  of  our  technical  services. 
Defective parts are our property.  

4. 

Are  not  covered  under  warranty  damage  caused  by  transportation,  neglect  or  poor  use, 
improper assembly or installation, as well as external influences such as: lightning strikes or 
power, flooding, humidity, etc..  

5. 

Lose  warranty,  all  appliances  that  are  not  being  used  according  to  the  instructions,  or 
connected to FEEDING NETWORKS not guarantee a constant voltage of 220/240V.  

6. 

The  warranty  does  not  cover  damages  for  personal  injury  or  damage  caused  directly  or 
indirectly in any capacity whatsoever. 

7. 

This  warranty  terminates  when  it  is  found  to  have  been  undergoing  repairs,  alterations  or 
interventions by any person not authorized by Jocel.  

 

THE WARRANTY EXPIRES

 

1.  With the modification or disappearance of the nameplate of the appliance. 

 

2.  Exceeded  the  period  of  2  years  for  home  appliances  and  06  months  for  industrial 

appliances,  warranty  expires  and  assistance  will  be  made  by  charging  the  costs  of 
manpower, according to current fees. 

 

 

TECHNICAL ASSISTANCE

 

 

For technical assistance request, our services are available through the following contacts:  

 

Telef.  00 351 252 910351 
Fax:   00 351 252 910367 
E-mail

[email protected]

 

http://www.jocel.pt 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

-23- 

Summary of Contents for JVAB030528

Page 1: ...VENTOINHA NEBULIZADORA VENTILADOR NEBULIZADOR MIST FAN JVAB030528 JVAP030511 MANUAL DE INSTRU ES MANUAL DE INSTRUCCIONES INSTRUCTION MANUAL...

Page 2: ...e recorre a um impulso e um circuito de alta oscila o com vista a produzir e fornecer oxig nio s mol culas Deste modo produzem se de facto esp cies de oxig nio reativo e esteriliza se o ar Visor da te...

Page 3: ...para n o derramar gua 3 Vire o dep sito de gua para que o fundo fique virado para cima 4 Retire a tampa do dep sito conforme ilustrado e acrescente gua 5 Volte a colocar a tampa no dep sito rode o dep...

Page 4: ...esta fun o TEMPORIZADOR Prima para definir o tempo de funcionamento pretendido m ximo de 8 horas com aumentos de 1 hora O mostrador LED apresenta o tempo definido VENTILA O Tr s op es normal natural...

Page 5: ...tricos afaste a ficha da gua N o toque na ventoinha se estiver a funcionar caso contr rio poder provocar ferimentos Afaste os pequenos objetos da prote o da ventoinha e tampa do nebulizador para impe...

Page 6: ...no interior da bacia seque com um pano Coloque 2 3 pingos de leo de m quinas no veio do motor Guarde a ventoinha num local fresco e seco Coloque a pastilha repelente de insectos E 2 5 x L 22 x P 35mm...

Page 7: ...Retire a gua do dep sito e substitua o O pulverizador n o funciona O flutuador b ia n o est em cima Manualmente coloque o flutuador b ia em cima A luz indicadora est acesa mas a ventoinha e a nebuliz...

Page 8: ...e acordo com as instru es ou ligados a REDES DE ALIMENTA O que n o garantem uma tens o constante de 220 240V 6 A Garantia n o abrange indemniza es por danos pessoais ou materiais causados directa ou i...

Page 9: ...relho VENTOINHA NEBULIZADORA Marca JOCEL Modelo JVAB030528 E JVAP030511 Est em conformidade com as seguintes directivas europeias e normas de aplica o Baixa Tens o 2006 95 CE EN 60335 1 2012 A11 2014...

Page 10: ...de gran oscilaci n por pulsos para generar mol culas de ox geno Esto producir de manera efectiva especies reactivas de ox geno esterilizando el aire Pantalla de temperatura Una serie de sensores t rm...

Page 11: ...a procurando no derramar agua 3 Gire el dep sito de agua de modo que la parte inferior quede hacia arriba 4 Retire la cubierta del dep sito seg n se indica y a dale agua 5 Vuelva a colocar el dep sito...

Page 12: ...se para ajustar la hora que desee en intervalos de 1 hora y hasta un m ximo de 8 horas La pantalla LED mostrar su selecci n VENTILACI N Esta funci n tiene tres modos normal natural dormir Cuando se en...

Page 13: ...PRECAUCIONES Para minimizar el riesgo de descarga el ctrica mantenga el cable alejado de fuentes de agua No toque el atomizador por ultrasonido mientras est en funcionamiento Podr a provocar lesiones...

Page 14: ...juague el interior Seque con un pa o Aplique 2 3 gotas de aceite para m quinas en el eje del motor Guarde el ventilador en un lugar fresco y seco Ponga la almohadilla repelente de insectos E 2 5 x A 2...

Page 15: ...sustituya el dep sito El atomizador no funciona El flotador no flota Tire del flotador manualmente La luz del indicador est encendida pero ni el ventilador ni el vaporizador funcionan 1 El ventilador...

Page 16: ...ad etc 5 Pierden la garant a todos los aparatos que no son utilizados de acuerdo con las instrucciones o conectados a las REDES DE ALIMENTACI N que no garanticen una tensi n constante de 220 240V 6 La...

Page 17: ...rato VENTILADOR NEBULIZADOR Marca JOCEL Modelo JVAB030528 Y JVAP030511 Cumple con las siguientes directivas europeas y normas de aplicaci n Baja Voltaje 2006 95 CE EN 60335 1 2012 A11 2014 EN 60335 2...

Page 18: ...an anion generator which uses a pulse and a high oscillation circuit in order to produce and oxygen molecules These will effectively produce reactive oxygen species and sterilize the air Temperature D...

Page 19: ...an start working HOW TO ADD WATER 1 Open the door as shown in diagram 2 Remove the tank by pulling it upward take care not to spill water 3 Turn the water tank so that the bottom side is facing upward...

Page 20: ...n the function stop TIMING Push to set the time that you need up to 8 hours in 1 hour increments The LED display will reflect your selection WIND Three settings normal natural sleeping Its normal when...

Page 21: ...t supplied 2 x AAA and or replace the batteries REMOTE CONTROL CAUTIONS To reduce the risk of electric shock keep plug away from water Do not touch ultrasonic atomizer while operating may result in in...

Page 22: ...te mist pipe spray cone if humidifier needs cleaned Empty excess water and use detergent for hard water stains inside the sink dry with a cloth Put 2 3 drops of machine oil in the motor shaft Store fa...

Page 23: ...racked 1 Clean water tank spray barrel and sink several times 2 Empty the water from the sink and replace tank Atomizer is not working The float is not up Manually pull float up Indicator light is on...

Page 24: ...d according to the instructions or connected to FEEDING NETWORKS not guarantee a constant voltage of 220 240V 6 The warranty does not cover damages for personal injury or damage caused directly or ind...

Page 25: ...below Product MIST FAN Brand JOCEL Model JVAB030528 AND JVAP030511 Complies with the following European directives and standards implementation Low Voltage 2006 95 CE EN 60335 1 2012 A11 2014 EN 6033...

Reviews: