44
A.
Construction and characteristics
•
Transportable terrace/garden heater with tank housing.
•
Casing in steel with painting.
•
Gas hose connections with metal clamp.
•
Heat emission from reflector.
B.
Specifications
•
Use propane, butane or their mixtures gas only.
•
Max. wattage: 11000 watts
•
Min. wattage: 5000 watts
•
Consumption:
APPLIANCE CATEGORY:
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(50)
I
3B/P(37)
TYPES OF GAS:
Butane
Propane
Butane, propane
or their mixtures
Butane, propane
or their mixtures
Butane, propane or
their mixtures
GAS PRESSURE:
28-30mbar
37 mbar
30 mbar
50mbar
37mbar
OUTLET PRESSURE OF
REGULATOR:
30mbar
37 mbar
30 mbar
50mbar
37mbar
•
Using the proper regulator according to outlet pressure of regulator as showed in the table above.
C.
Table of injector
APPLIANCE CATEGORY:
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(50)
I
3B/P(37)
TYPES OF GAS:
Butane
Propane
Butane, propane
or their mixtures
Butane, propane
or their mixtures
Butane, propane
or their mixtures
GAS PRESSURE:
28-30mbar
37 mbar
30 mbar
50mbar
37mbar
TOTAL HEAT
INPUT (Hs): (Qn)
11kW (G30: 800g/h; G31: 786g/h)
INJECTOR SIZE:
1.75 mm for main burner
0.22 mm for pilot burner
1.55 mm for main
burner
0.22 mm for pilot
burner
1.60 mm for main
burner
0.22 mm for pilot
burner
The marking
,
for example
,
1.75 on the injector
,
indicates that the size of injector is 1.75 mm
•
The hose and regulator assembly must conform to local standard codes.
•
Regulator outlet pressure should meet the corresponding appliance category in B.
Specification.
•
The appliance requires approved hose in 0.6m length.