63
Run Waiting
5
Figure8-5 Countdown interface
If the start-stop mode of the system is manual (factory default setting), long
press the "ON/OFF" key for 3 s, and the inverter will start up and run .
Note
!
●
The default mode of inverter is manual start -stop mode. W hen inverter
power for the first time, it need key -press to start the inverter to drive
pump.(Run after long-
time press “ON/OFF"), at the same time, manual
start-stop mode will change into automatic start-stop mode directly.
●
Press “ON/OFF” stop the inverter and it will get started while long -time
pressing “ON/OFF”, if not do like this, the system won’t start.
●
The inverter can work at regular intervals, that is, the inverter automatically
stops after the set working time. For details, please refer to "
8.3.2.1 Timing
Shutdown Time Setting
" and "
8.3.4 Parameter Setting
".
●
The long button time described in this article is approximately 3 seconds.
●
LCD display two lines of characters .
After inverter initializing, main interfaces will be displayed circularly:
Ppv
R_Mode
Ipv
Vdc
Pgrid
State_AC
Iout
Fout
Run/Stop
D-Mode
OF-F