46
304
Grid lock phase
error
305
Invert relay KM1
turn on fault
hardware failure
contact the
customer service
307
Grid relay KM3
turn on fault
309
Soft start fault
KM4
315
Slave init error
Basic fault information of lithium batteries
Lithium
battery
type
fault
code
implication
fault
phenomenon
handling method
remark
ATX
BMS
fault
400
Total overvoltage
Stop charging
The inverter is
controlled by
itself without
operation
Failure with
yellow-light
401
Single
overvoltage
Stop charging
The inverter is
controlled by
itself without
operation
402
Total
undervoltage
Start the power
grid charging,
stop the inverter
Please charge in
time when the
battery is low
403
Single
undervoltage
Start the power
grid charging,
stop the inverter
Please charge in
time when the
battery is low
404
Dsicharge high
temperature
Stop the inverter
contact the
customer service
405
Charge high
temperature
Stop charging
contact the
customer service
406
Dsicharge low
temperature
The working
environment of
the battery pack
is not suitable
below 0
℃
Please heat the
battery pack or
transfer it indoors
407
Charge low
temperature
The working
environment of
the battery pack
is not suitable
Please heat the
battery pack or
transfer it indoors