44
aging or not
115
Storage rw fault hardware failure
contact the
customer service
Inverter
failure
200
Bat overvoltage
Whether the
battery is
connected
Cell aging
Abnormal battery
voltage causes
machine damage
1. Check whether
the battery side
switch is closed
2. Check the
battery voltage
level
3, check whether
the battery is
aging
24V
machine
overpressur
e point: 32V
Overpressu
re point of
48V
machine:
64V
201
Bat undervoltage
Whether the
battery has been
overdischarged
Battery voltage
class
1. Check the
battery voltage
level
2. Check whether
the battery is
overreleased
3, check whether
the battery is
aging
24V
machine
overpressur
e point: 32V
Overpressu
re point of
48V
machine:
64V
202
Invert output hard
overcurrent
Excessive load
current
Short circuit of
load
1. Observe
whether the fault
is automatically
restored
2. Check whether
the load is too
heavy or short
circuit
203
Invert output soft
overcurrent
204
Invert output soft
overvoltage
load sudden
change
Restart the boat
switch
205
Inverter up mos
overheating
Fan failure or
blockage of inlet
and outlet
1.Check whether
there is any
shielding around
the chassis
2. Check whether
the inlet and
outlet of the
chassis are
blocked
3. Check whether
206
Inverter down
mos overheating
Summary of Contents for JNF3KLF24V-A-V2