PWM Mode
Solar Charge Controller Manual
ADD
:
No.99 Yonghe Rd,High-Tech Zone,Hefei,Anhui
Phone
:
0551-65372576
http://www.hfjnge.com
- 8 -
Explain
:
monitoring background supports PC upper computer, supports WIFI module and GPRS
module to expand and realize APP cloud monitoring (optional). For details, please refer to operating
manual of PC upper computer and APP;
Step 3: checking connection
Check whether polarity of all wiring is correct and whether terminals are locked;
Step 4: Boot sequence
Recommended turn on, turn off sequence
:
close battery switch, photovoltaic switch or load switch in
turn
;
shut down photovoltaic and load switch, and then turn off battery switch.
3.4 Photovoltaic array requirements
Parameter
Model
JN-K
JN-R
System rated voltage
12V
24V
48V
12V
24V
48V
PV Max VOC
22V
44V
88V
22V
44V
88V
3.5 Cable type selection requirements
The following table is conversion of copper wire diameter size according to current level. The actual
diameter size of wire cable metal should be greater than or equal to the data in the table
Parameter
Model
JN-K
JN-R
Current/A
10
20
30
30
40
50
60
Wire dia/mm2
2
4
6
6
8
10
12
AWG
14
11
9
9
8
7
6
Warning
!
1.Electric shock risk
!
Do not touch live parts of high voltage pv module with bare hands
;
2.Please ensure that solar array voltage in the system does not exceed the maximum input voltage
range of controller
;
3.The system needs to connect inverter, please connect inverter directly to battery, do not connect to
load end of controller;