JNGE Power JN-K Series Product Manual Download Page 3

PWM Mode

Solar Charge Controller Manual

ADD

No.99 Yonghe Rd,High-Tech Zone,Hefei,Anhui

Phone

0551-65372576

http://www.hfjnge.com

- 2 -

1.Safety instructions

1.1

Security identity

The following safety symbols may appear in this manual with the following meanings

Safety symbols

meaning

dangerous

ignoring safety warnings,it can lead to serious accidents that could result in

personal injury.

warning

Indicates that if safety warnings are ignored, there is a risk of serious injury

accident, serious damage to equipment or interruption of major business

attention

Indicates the risk of moderate injury accident, moderate equipment damage or

partial business interruption if safety warnings are ignored.

instructions

Indicates that the content is additional information to the body.

For electrical and electronic equipment, safety involves the whole process of installation,

commissioning, operation and maintenance

So

Improper use or improper operation will endanger the

life and personal safety of operators or third parties as well as the safety of equipment

In order to avoid

casualties and equipment damage, the operation and maintenance process must strictly comply with the

following dangerous, warning and attention to the safety information tips.

1.2

Safety instructions

Warning

All installation of the controller must be performed by a professional technician

The professional

technical personnel must go through the special training, read the manual completely and master the

operation related safety matters.

The company shall not be liable for any injury caused by non-professional installation operation.
Failure to install and operate the controller according to the instructions in this manual will not be

covered by our warranty.

Before installation

Attention !

When receiving the product, please check whether controller is damaged in the process of

transportation. If there is any problem, please contact the company or the transportation company

immediately.

During installation

Before installing the controller, make sure that the controller is not electrically connected or

energized.

Warning

The controller damage caused by the following circumstances or other losses will not be covered by

our warranty.

When the photovoltaic array is configured, ensure that the maximum short-circuit current of the dc

side is within the allowable range of the controller, otherwise the controller may be damaged

irrecoverable.

When the photovoltaic array is configured, it is important to ensure that the open circuit voltage of

each photovoltaic cluster string does not exceed the maximum input range of the controller, otherwise it

will cause non-recoverable damage to the controller.

Summary of Contents for JN-K Series

Page 1: ...Anhui JNGE Power Co LTD JN K JN R Series PWM Solar Charge Controller Product manual Anhui JNGE Power Co LTD ADD No 99 Yonghe Rd High Tech Zone Hefei Anhui Phone 0551 65372576 ...

Page 2: ...stallation instructions 5 3 1 Installation precautions 5 3 2 Installation instructions 6 3 3 Wiring 7 3 4 Photovoltaic array requirements 8 3 5 Cable type selection requirements 8 4 Instructions for operation 9 4 1 LCD display 9 4 2 Key 10 4 3 Setting operation 11 5 Equipment parameters 12 5 1 Protection function 12 5 2 Troubleshooting 13 5 3 System maintenance 14 6 Warranty commitment 14 7 Equipm...

Page 3: ...on tips 1 2 Safety instructions Warning All installation of the controller must be performed by a professional technician The professional technical personnel must go through the special training read the manual completely and master the operation related safety matters The company shall not be liable for any injury caused by non professional installation operation Failure to install and operate t...

Page 4: ...l the controller in flammable or explosive places or storage places for flammable or explosive materials Do not install the controller where there is explosive danger Do not install the controller where lightning may strike Do not install the controller where there is a lot of salt spray When controller is running it is necessary to ensure the normal air convection around it The controller shall b...

Page 5: ...tem performance Adopt imported power MOSFET as electronic switch low loss high reliability LCD and button interface are adopted to facilitate the display and operation With temperature compensation control algorithm the system automatically adjusts charging and discharging parameters to improve the service life of battery Using RS485 communication bus communication speed is fast communication prot...

Page 6: ...ve pole Battery terminal 4 BAT Battery negative pole 5 LOAD DC load positive pole Battery load output terminal 6 LOAD DC load negative pole 7 Temp sensor External temperature test terminal Measure external battery temperature 8 RS485 Communication port Realize upper computer WIFI GPRS communication monitoring 9 USB DC5V output 5V USB output 0 5A 3 Installation instructions 3 1 Installation precaut...

Page 7: ...h the charging voltage of the controller and the recommended charging current range Danger Explosion danger Never install controller and battery in the same confined space Do not install in a confined space where battery gas may accumulate 3 2 Installation instructions Step 1 Select installation site Avoid installing controller in direct sunlight high temperature and water easily and ensure good v...

Page 8: ...nnect the battery load photovoltaic module temperature sensor monitoring background upper computer WIFI module or GPRS module in turn disconnect all switches in the wiring process pay attention to distinguish between positive and negative terminal cable access Before connecting battery make sure battery is in a normal state to ensure the normal operation of system Step 2 wiring Lock cable to the t...

Page 9: ... off battery switch 3 4 Photovoltaic array requirements Parameter Model JN K JN R System rated voltage 12V 24V 48V 12V 24V 48V PV Max VOC 22V 44V 88V 22V 44V 88V 3 5 Cable type selection requirements The following table is conversion of copper wire diameter size according to current level The actual diameter size of wire cable metal should be greater than or equal to the data in the table Paramete...

Page 10: ... in data display area Under under voltage field to set battery overdischarge voltage when battery undervoltage field flashing Under R Under recover voltage field lights up to set battery overdischarge return voltage OVD Over charging voltage field lights up battery overcharge pressure can be set when battery overcharge field flashing OVD R Over charging recover field lights up can set battery over...

Page 11: ... Time2 Time 3 set field lights up in street lamp mode can be set time control third period light control the second light L CON V Light control voltage set field lights up first display area shows 1 can set light on light on voltage After light control on setting is completed first display 2 can set light control off light control off voltage ERROR Alarm indication field lights up when there is a ...

Page 12: ...ttings interface press ESC button in any interface to exit setting interface JN K no ESC stop in Settings interface for 5 seconds to exit the Settings interface back to standby screen other general parameter Settings are similar to undervoltage Settings Figure 4 3 General parameter setting flowchart of battery undervoltage point setting 4 4 2 Light control parameter setting Figure 4 4 Light contro...

Page 13: ... When charging voltage of photovoltaic array exceeds rated input voltage range of controller red alarm light flashes PV over voltage alarm can be detected through upper computer or APP controller stops charging battery Reverse polarity of battery When battery polarity is reversed controller will not work and will not be damaged After correcting wiring error switch will continue to work normally Ba...

Page 14: ...al it means load power is too large or battery voltage and capacity are too low overload may easily lead to under voltage protection 2 Disconnected load controller still gives an alarm battery voltage has not recovered to over discharge recovery set value It is necessary to charge battery group through photovoltaic or other ways to make battery group voltage reach set value of recovery point befor...

Page 15: ...ailed replace failed arrester in time to prevent lightning damage to controller or even other equipment of user Attention electric shock risk Make sure that all power supply of controller is disconnected when above operation is carried out and check or operate accordingly 6 Warranty commitment Controller is guaranteed free of charge for one year starting from the date of sale Maintenance procedure...

Page 16: ...Vbat 1V Rated charging current 10A 20A 30A 30A 40A 50A 60A Charging drop 0 7V Discharging drop 0 2V Static loss 0 3W Communications RJ45 interface RS485 communication USB output 5V 0 5A Operating environment parameters Liquid crystal display temperature range 20 75 Ambient temperature 20 50 Storage temperature 30 70 Humidity 10 90 Protection grade IP30 Boost charge duration min 120 Working state d...

Page 17: ...2 string 3 string default Over voltage v 10 5 15V 21 30V 42 60V 13 05V Overtvoltage recover v 10 5 15V 21 30V 42 60V 12 6V Charging limit voltage v 10 5 15V 21 30V 42 60V 12 6V Boost charging voltage v 10 5 15V 21 30V 42 60V 12 4V Boost return voltage v 10 5 15V 21 30V 42 60V 12V Floating voltage v 10 5 15V 21 30V 42 60V 12 4V Over discharging voltage v 6 13 5V 12 27V 24 54V 9 6V Over discharging ...

Page 18: ...Anhui Phone 0551 65372576 http www hfjnge com 17 8 Installation dimension Figure 8 1 JN K Installation structure diagram Figure 8 2 JN K Schematic diagram of appearance structure Figure 8 3 JN R Installation structure diagram Figure 8 4 JN R Schematic diagram of appearance structure ...

Page 19: ... controller 1 2 Product manual 1 3 External battery temperature probe 1 4 RJ45 To USB module 1 Communication function of upper computer optional 5 Cable 1 6 Upper computer installation CD 1 7 Host computer communication instructions 1 8 RJ45 To GPRS communication module 1 APP GPRS optional 9 0 2m Special network cable 1 10 APP User manual 1 11 RJ45 To WiFi communication module 1 APP WiFi optional ...