![JLG 3124288 Manual Download Page 33](http://html1.mh-extra.com/html/jlg/3124288/3124288_manual_2020135033.webp)
SECTION 4 - OPERATION - (RS)
3124288
– JLG Lift –
4-3
4.4 PERSONALITIES MENU (RS)
The following parameter in the PERSONALITIES, LOAD
menu adjust performance of the LSS. All adjustments
must be made in Access Level 1 (33271).
4.5 CALIBRATION MENU (RS)
NOTE:
The Load Sensing System cannot be calibrated with-
out first calibrating the machines Angle Sensor.
Angle Sensor Calibration (RS Only)
To access the Calibration Angle Menu, use the LEFT and
RIGHT Arrow keys to select CALIBRATION from the Top
Level Menu. Press the ENTER key to select the menu.
Press the LEFT and RIGHT arrow keys to select ANGLE
from the CALIBRATION menu. Press the ENTER key to
view the submenu.
Should the Analyzer read CAL ANGLE:FAIL at any time
during the calibration procedure, reference the table
below for the failure listed by the Analyzer.
NOTE:
The Calibration Menu is not available in Access
Level 2.
Upon entry to the Calibration, ANGLE Menu, the analyzer
will display:
CAL ANGLE:
YES:ENTER, NO:ESC
Pressing the ESC key will return the user to the top level
menu and not disturb the prior calibration information.
Table 4-3. Personalities Menu Description (RS)
SUBMENU
(Displayed on
Analyzer 1st line)
PARAMETER
(Displayed on
Analyzer 2nd Line)
DESCRIPTION
LOAD:
OVR DBNCE 0.3S
Displays/Adjusts the
debounce delay for an
overload.
OVR HOLD 5.0S
Displays/Adjusts the
minimum delay
before an overload
can be resolved.
CAL ANGLE:
YES:ENTER NO:ESC
Go to Discount-Equipment.com