background image

7

Input Mode

2 Ch. | 4 Ch.

All | 3&4

1&2 | Sum

Preouts From

Remote Level Mode

4 Channel Amplifier

Rem. | Offset | Signal

Input Voltage

Low | High

Turn-On Mode

 

If you wish to send four discrete channels into 

the XD400/4, simply use all four inputs and set 
the “Input Mode” switch in the “4 Ch.” position.

If you wish to use only two channels of input to 

deliver signal to all four amplifier channels, set the 

“Input Mode” switch to “2 Ch.” and use only the 
inputs to channels 1 and 2. In this mode, channel 
3 will operate with the channel 1 signal and 
channel 4 will operate with the channel 2 signal.

 

Input Voltage Range:

 

A wide range of signal input voltages can 

be accommodated by the XD400/4v2’s input 
section (200mV – 8V). This wide range is split 
up into two sub-ranges, accessible via the “Input 

Voltage” switch:

“Low”: for preamp level signals

“High”: for speaker level signals

This switch affects all channels of the amplifier 

equally. The “Low” position on the “Input 

Voltage” switch selects an input sensitivity 
range between 200mV and 2V. This means that 
the “Input Sens.” rotary controls will operate 
within that voltage window. If you are using 
an aftermarket source unit, with conventional 
preamp level outputs, this is the position you 
should select.

The “High” position on the “Input Voltage” 

switch selects an input sensitivity range between 
800mV and 8V. This is useful for certain high-
output preamp level signals as well as speaker 
level output from source units and small 
amplifiers. To use speaker level sources, splice the 
speaker output wires of the source unit or small 
amplifier onto a pair of RCA cables or plugs, 
or use the JL Audio ECS Speaker Wire to RCA 
adaptor (XD-CLRAIC2-SW).

Line output converters are usually not needed 

with the XD400/4v2. If you find that the output 
cannot be reduced sufficiently with a direct 
speaker level signal applied to the amplifier and 
the “Input Voltage” switch in its “High” position, 
you may use a line output converter or voltage 
divider to reduce the signal level.

INPUT SENSITIVITY CONTROLS

The control labeled “Input Sens.” can be used 

to match the source unit’s output voltage to the 
input stage of the XD400/4v2 for maximum clean 
output. Rotating the control clockwise will result 
in higher sensitivity (louder for a given input 
voltage). Rotating the control counter-clockwise 
will result in lower sensitivity (quieter for a given 
input voltage).

 

Input Mode

2 Ch. | 4 Ch.

All | 3&4

1&2 | Sum

Preouts From

Remote Level Mode

4 Channel Amplifier

Rem. | Offset | Signal

Input Voltage

Low | High

Turn-On Mode

 

To properly set the amplifier for maximum 

clean output, please refer to Appendix A (page 
14) in this manual. After using this procedure, 
you can then adjust the “Input Sens.” levels 
downward if this is required to achieve the 
desired system balance.

Summary of Contents for XD 400/4v2

Page 1: ...allation equipment to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughly to familiarize yourself with...

Page 2: ...space provided below The serial number can be found on the bottom panel of the amplifier and on the amplifier packaging Serial Number INSTALLATION APPLICATIONS This amplifier is designed for operatio...

Page 3: ...ventilated environment and in a manner which does not interfere with your vehicle s safety equipment air bags seat belt systems ABS brake systems etc You should also take the time to securely mount th...

Page 4: ...eaker systems to the amplifier mounting location 6 Find a good solid metal grounding point close to the amplifier and connect the negative power wire to it using appropriate hardware use of the JL Aud...

Page 5: ...the set screw firmly taking care not to strip the head of the screw The ground connection should be made using 8 or 4 AWG wire and should be kept as short as possible while accessing a solid piece of...

Page 6: ...ventional 12 V turn on leads Depending on the characteristics of the audio signal one of the following methods may work better than the other We recommend trying DC Offset Sensing first as it does not...

Page 7: ...ts an input sensitivity range between 800mV and 8V This is useful for certain high output preamp level signals as well as speaker level output from source units and small amplifiers To use speaker lev...

Page 8: ...audio system Input Mode 2 Ch 4 Ch All 3 4 1 2 Sum Preouts From Remote Level Mode nal Input Voltage Low High e 1 Filter Mode Controls The XD400 4v2 employs 12dB per octave filters for each pair of cha...

Page 9: ...y added to the system This pass through preamp output can be configured two different ways using the switch labeled Preouts From 1 1 2 the preamp output delivers the same signal that is connected to t...

Page 10: ...put of two amplifier channels to drive a single load When bridged each channel produces signals of equal magnitude but opposite polarity The combined output of the two channels provides twice the outp...

Page 11: ...ticking or thumping noise in the output Over current conditions can be caused by a speaker impedance lower than the optimum load impedance range for the amplifier or a short circuit in the speaker wi...

Page 12: ...D400 4v2 s Input Sens settings and will not be user adjustable from the front of the vehicle B Fade Subwoofer Level vs HF Level Req uired a source unit or processor with two pairs of stereo outputs In...

Page 13: ...pair of source unit outputs is connected to the subwoofer amplifier inputs Res ult with this option the user has the ability to fade the level of the subwoofer amplifier s input relative to the HF ch...

Page 14: ...input sensitivity adjustment according to the nominal impedance of the speaker system connected to the amplifier outputs 6 Verify that you have disconnected the speakers before proceeding Play a track...

Page 15: ...tio 104 dB referred to rated power A weighted 20 Hz 20 kHz noise bandwidth 84 dB referred to 1W A weighted 20 Hz 20 kHz noise bandwidth Frequency Response 12 Hz 22 kHz 0 1dB Damping Factor 150 4 ohms...

Page 16: ...ay is required To test for this problem jump the 12VDC wire to the Remote terminal to see if the amplifier turns on I get a repetitive ticking or popping sound coming out of the speaker s Check the sp...

Page 17: ...while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be amplified by...

Page 18: ...JL Audio XD400 4v2 Owner s Manual INSTALLATION NOTES Use this diagram to document your amplifier s switch and control positions 4 Channel Amplifier Rem Offset Signal Input Voltage Low High Turn On Mo...

Page 19: ...19...

Page 20: ...etail and no warranties whether express or implied shall apply to this product thereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you Thi...

Reviews: