Make sure the array of modules installed with the Maximum permitted system voltage
and the rating current and voltage of the sub-equipments such as regulators and
inverters. The maximum permitted system voltage (DC) of the modules
(
UL 1000V
series
)
sold in America and Canada is 1000V.
This module has a Class C Fire Rating
(
only in Canada
)
or Module Fire performance
type 1 (only in America) and must be installed over a roof which is with appropriate
fire resistance. Before mounting the module, please consult your local building
department to determine approved roofing materials.
The modules are qualified for application class A, and modules qualified for safety
through UL1703 within this application class are considered to meet the requirements
of Safety Class II
The Fire rating is Class C in Canada, but the Module Fire performance is type 1 in
America with the specified construction in below table, when used with a listed
mounting system that has been rated as a Class A System when installed with type 1
modules, is suitable to maintain the System Class A Fire Rating in America.
Module model
Specific construction
Marking
All
Superstrate: 3.2~4.0 mm thick;
EVA: 0.25~0.45 mm thick;
Substrate: 0.34 mm ~ 0.385 mm thick;
Frame: Types “40mm by 20mm” or
“40mm by 35mm” or “700-0218”
Module Fire Performance:
Type 1
1.3 Warnings
PV modules generate DC electrical energy when exposed to sunlight or other light
sources. Active parts of module such as terminals can result in burns, sparks, and
lethal shock
Artificially concentrated sunlight shall not be directed on the module or panel.
Summary of Contents for JKMxxxM-60 Series
Page 1: ...JinkoSolar Photovoltaic Module User Manual UL1703 ...
Page 22: ... 20 Note ...