Rev. C
- 11
-
Module type
Cell type
Cell
quantity
Dimension(mm)
A*B
J
K
M
O
N
P
JKMXXXP-72
JKMXXXPP-72
JKMXXXP-72B
JKMXXXPP-72B
JKMSXXXP-72
JKMSXXXPP-72
JKMxxxPP-72(Plus)
Poly
6*12
1956*992
400
480
5~11
0.5~2mm
≥
14
>
2mm
JKMXXXM-72
JKMXXXM-72B
JKMSXXXM-72
Mono
6*12
1956*992
400
480
5~11
0.5~2mm
≥
14
>
2mm
JKMXXXP-60
JKMXXXPP-60
JKMXXXP-60B
JKMXXXPP-60B
JKMSXXXP-60
JKMSXXXPP-60
JKMxxxPP-60(Plus)
Poly
6*10
1650*992
400
420
5~10
0.5~2mm
≥
14
>
2mm
JKMXXXM-60
JKMXXXM-60B
JKMSXXXM-60
Mono
6*10
1650*992
400
420
5~10
0.5~2mm
≥
14
>
2mm
Table 1 above: Mechanical dimensions when modules installed at long side with Clamp
3. Wiring and connection
a) Before this procedure, please read the operation instructions of the PV system
carefully. Make wiring by Multi-connecting cables between the PV modules in
series or parallel connection, which is determined by user’s configuration
requirement for system power, current and voltage.
b) PV module connected in series should have similar current, and modules must not
be connected together to create a voltage higher than the permitted system
voltage. The maximum number of modules in series depends on system design,
the type of inverter used and environmental conditions.
c) The maximum fuse rating value in an array string can be found on the product
label or in the product datasheet. The fuse rating value is also corresponding to the