-16-
Group 43
2194*1034 & 2205*1032
390
540
Group 47
2168*1021 & 2168*1024 &
2182*1029 & 2182*1032
385
530
Table 4: Mechanical dimensions of modules installed with clamps on long side of frame
According to IEC 61215 for a maximum positive design loading of below 3600Pa, and negative design
loading 1600Pa, with 1.5 times safety factor
.
2.3.2.2 Clamp Mounting on Short Sides of the Frames
Figure 7: Installation of clamps on short side of frames
Module type
Max. Design Pressure:
1067Pa (positive )
&1067Pa (negative)
mechanical load
1067Pa (positive )
&1067Pa (negative)
mechanical load
Module dimensions(mm)
A*B
J
K
J
K
60P
Height of the frame
(
mm
)
35
30
Group 1
1650*992 & 1665*1002
50
240
100
240
Group 2
1665*992 & 1684*1002
50
240
100
240
Group 3
1650*992 & 1665*1002
50
240
100
240
Group 4
1665*992 & 1684*1002
50
240
100
240
Group 5
1650*992 & 1665*1002
50
240
100
240
Group 6
1665*992 & 1684*1002
50
240
100
240
Group 7
1650*992 & 1665*1002
50
240
100
240
Group 8
1665*992 & 1684*1002
50
240
100
240
Group 9
1665*992 & 1684*1002
1672*992 & 1704*1008
50
240
100
240
Group 20
1704*1008
50
240
100
240
Group 22
1684*1002
50
240
100
240
Group 30
1704*1008
50
240
100
240
Group 46
1684*1002
50
240
100
240
72P
Height of the frame
(
mm
)
40