connectors is more than 10A), otherwise cables and connectors will become
overheating for large current. Please pay attention: the temperature limit of cables
is 85
℃
and the temperature limit of connector 105
℃
e) All module frames and mounting racks must be properly grounded in accordance
with local and national electrical codes. Attach the equipment grounding conductor
to the module frame using the hole and hardware provided. Not that a stainless
steel star washer is used between the ground wire and module frame (see picture
below).This washer is used to avoid correosion due to dissimilar metals.Tighten the
screw securely.
f) Follow the requirements of applicable local and national electrical codes.
g)These modules contain factory installed bypass diode .if these modules are
incorrectly connected to each other, the bypass diodes, cable or junction box may
be damaged.
h) The cable of the junction box is 900mm, as showed in below picture, please take
the cable length into consideration before designing the wiring layout.